![TeraBee Evo Thermal 33 User Manual Download Page 4](http://html1.mh-extra.com/html/terabee/evo-thermal-33/evo-thermal-33_user-manual_1088191004.webp)
Figure 2. TeraRanger Evo two-part design
When choosing a place for mounting, please consider the following recommendations:
● Choose a place which is in accordance with the optical constraints listed below
● Mounting close to sources of heat or strong electromagnetic fields can decrease the
sensing performance
● Do not mount anything directly in front of the sensor or in a cone of approximately
±90° around the central optical axis of the sensor
● Please consider that dust, dirt and condensation can affect the sensor’s performance
● To obtain a correctly positioned (not inverted or rotated) thermal image, please mount
the sensor with the USB or UART connector pointing left (if facing sensor’s lens). See
Figure 3 for visual instructions. This also applies when hand-testing Evo Thermal via
our graphical user interface (ref. Section 3.1.2).
Figure 3. Module orientation for correct thermal image. Evo Thermal 33.