14
[email protected] | www.teptron.com | Box 1009, 432 13 Varberg
24
Calibration of endpoints
MOVEZ is calibrated with the physical buttons (picture 2, position 1, 2 and 3). Because MOVEZ can be installed in
many ways the buttons up (picture 2, position 1) and down (picture 2, position 3) can make the product on which
MOVEZ is installed on run in different directions depending on installation. After the endpoints are set the buttons at
the device will however be correct and always give correct action.
The two buttons up and down will make the motor either go to up (Open, ON or position 100) endpoint or down
(Close, OFF or position 0) endpoint.
Calibration of “up” (Open, ON or position 100). This is the maximum open position.
Procedure explained below,
1.
Push and hold in the stop button (picture 2, position 2).
2.
With the stop button pushed in, push and hold in the up button (picture 2, position 1).
3.
Let go of both buttons. The led indicator (picture 2, position 5) will then blink slow green to indicate that the
device
is in calibration “
up
” mode. Use the
up and down buttons to set the maximum
“up”
position. The
“up”
position is the position when the product on which MOVEZ is installed at
DOSE NOT cover the window
.
4.
When the desired
“up”
position is found click the stop button. The position will now be saved, and the
blinking will stop.
Calibration of “down” (Close, OFF or pos
ition 0). This is the maximum closed position.
Procedure explained below,
1.
Push and hold down the stop button (picture 2, position 2).
2.
With the stop button pushed in, push and hold in the down button (picture 2, position 3).
3.
Let go of both buttons. The led indicator (picture 2, position 5) will then blink rapid green to indicate that the
device is in calibration
“down”
mode. Use the up and down buttons to set the maximum
“down”
position.
The
“down”
position is the position when the product on which MOVEZ is installed at
DO cover the window
.
4.
When the desired
“down”
position is found click the stop button. The position will now be saved, and the
blinking will stop.