background image

14 

[email protected] | www.teptron.com | Box 1009, 432 13 Varberg 

24

 

Calibration of endpoints 

MOVEZ is calibrated with the physical buttons (picture 2, position 1, 2 and 3). Because MOVEZ can be installed in 
many ways the buttons up (picture 2, position 1) and down (picture 2, position 3) can make the product on which 
MOVEZ is installed on run in different directions depending on installation. After the endpoints are set the buttons at 
the device will however be correct and always give correct action. 

The two buttons up and down will make the motor either go to up (Open, ON or position 100) endpoint or down 
(Close, OFF or position 0) endpoint. 

 

 

Calibration of “up” (Open, ON or position 100). This is the maximum open position.

 

Procedure explained below, 

1.

 

Push and hold in the stop button (picture 2, position 2). 

2.

 

With the stop button pushed in, push and hold in the up button (picture 2, position 1). 

3.

 

Let go of both buttons. The led indicator (picture 2, position 5) will then blink slow green to indicate that the 
device 

is in calibration “

up

” mode. Use the 

up and down buttons to set the maximum 

“up”

 position. The 

“up”

 position is the position when the product on which MOVEZ is installed at 

DOSE NOT cover the window

4.

 

When the desired 

“up”

 position is found click the stop button. The position will now be saved, and the 

blinking will stop. 

 

 

Calibration of “down” (Close, OFF or pos

ition 0). This is the maximum closed position. 

Procedure explained below, 

1.

 

Push and hold down the stop button (picture 2, position 2). 

2.

 

With the stop button pushed in, push and hold in the down button (picture 2, position 3). 

3.

 

Let go of both buttons. The led indicator (picture 2, position 5) will then blink rapid green to indicate that the 
device is in calibration 

“down” 

mode. Use the up and down buttons to set the maximum 

“down”

 position. 

The 

“down”

 position is the position when the product on which MOVEZ is installed at 

DO cover the window

4.

 

When the desired 

“down”

 position is found click the stop button. The position will now be saved, and the 

blinking will stop. 

 

 

 

Summary of Contents for MOVEZ

Page 1: ...MOVEZ User manual MOVEZ Z Wave controlled motor for indoor blinds and shades...

Page 2: ...FIGURATION PARAMETERS 10 15 DEVICE CLASSIFICATION 11 16 SUPPORTED COMMAND CLASSES 11 17 FLIRS 11 18 LOCAL SWITCH OPERATIONS 12 19 LOW BATTERY WARNINGS 12 20 LED INDICATIONS MAIN DEVICE 12 21 BATTERY P...

Page 3: ...ifications to the product Before connecting a power adapter batteries or blinds and shades to the product carefully read the warnings and the product manuals of those products and it s important to on...

Page 4: ...ce Le pr sent appareil est conforme aux CNR d ISED applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de br...

Page 5: ...is installed enclosed wall bracket MOVEZ uses a Z Wave radio and it is a Security S2 SmartStart enabled Z Wave Plus Product It uses S2 UNAUTHENTICATED SECURITY CLASS as its highest level of security H...

Page 6: ...6 info teptron com www teptron com Box 1009 432 13 Varberg Picture 2 Main device Picture 3 Parts...

Page 7: ...ers are set to their default values Note The term EXCLUSION REMOVING UNPARING implies to the same meaning Exclusion procedure explained below 1 Set gateway into the exclusion mode See gateway user man...

Page 8: ...ilevel Switch Set Last known non zero value if value of configuration parameter 03 is set to 0 See configuration parameters section for more information Default last known value is 100 Basic Set 0 map...

Page 9: ...nt with 1 Status field reports Success with More Status Updates bit set to 0 2 Duration field reports Already at the target value 13 Associations MOVEZ supports association command class with two asso...

Page 10: ...ures the down speed of the motor 1 lowest and 100 highest speed Table 5 Parameter 03 Basic Set 0xFF support Size 1 byte decimal Range 0 to 1 Default value 1 Description The value of the parameter deci...

Page 11: ...TTERY Ver 01 17 FLIRS A key feature of the popular Z Wave wireless communications protocol that s particularly relevant to designers of battery powered devices as well as other home automation and sec...

Page 12: ...ng with every low battery warning notification MOVEZ also sends current battery report 20 LED Indications main device Red LED Green LED Meaning OFF Blink fast Device in calibration mode Blink fast Bli...

Page 13: ...r source Charging starts when a USB power adapter is attached to the battery pack It will take about 13 hours to fully charge a battery and because the charger is smart it will automatically turn off...

Page 14: ...ns The led indicator picture 2 position 5 will then blink slow green to indicate that the device is in calibration up mode Use the up and down buttons to set the maximum up position The up position is...

Page 15: ...nside MOVEZ has a torque of about 1Nm and incorrect installation and or usage can be dangerous Make sure that the cord or bead chain of the product you intend to install MOVEZ on is compatible do not...

Page 16: ...ferent sizes of bead chain and connectors exist and MOVEZ is designed to fit as many as possible but compatibility to make sure MOVEZ fits the product it s about to be installed on need to be establis...

Page 17: ...e in the spool lines up correctly with the hole on the motor output axel The metal pieces that are bent around the cord loop center hole should grip the motor output axel 27 1 Mounting cord loop to pu...

Page 18: ...just pulling a cord need some preparation in order for MOVEZ to operate them 1 Remove all plastic parts from the cord 2 After removing the plastic parts make a knot on the end of the cord Picture 9 Pr...

Page 19: ...3 Varberg 29 Ways to get correct position for installation Option 1 Use a template to mark up the location for the device Figure 12 Mounting plate mark up Option 2 Use the mounting plate to mark up th...

Page 20: ...tron com www teptron com Box 1009 432 13 Varberg The wall mounting plate used to attach the MOVEZ to the wall Picture 14 Mounting plate Use screws and anchor to attach mounting plate to wall Picture 1...

Page 21: ...ng plate position and use Philips screwdriver or drill to install it If the wall plug is used a hole need to be drilled before insertion of the plug and then use of the screw Picture 16 Fixing Mountin...

Page 22: ...ron com Box 1009 432 13 Varberg 31 Attach main device to mounting plate Push main device towards the mounting plate to attach the main device to the wall mounting plate Picture 18 Fixing main device P...

Page 23: ...3 Varberg 32 Installing battery pack Make sure to alien the battery pack to main device and push it from underneath Battery pack connection should line up with main device connection Picture 20 Attach...

Page 24: ...eront pr server les ressources naturelles et s assurer qu il est recycle de mani re prote ger la sante humaine et l environnement Europa ische Union Informationen zur Entsorgung Das oben aufgef hrte S...