12
[email protected] | www.teptron.com | Box 1009, 432 13 Varberg
18
Local switch operations
It is will be possible to click on either the up or the down button (picture 2, position 1 and 3) to make MOVEZ go to
the respective end positions. MOVEZ can always be stopped by clicking the stop button at the device. This is true no
matter if the initial run command originates from the push/click of buttons “
up
” or “
down
” or from the radio.
19
Low battery warnings
Low battery warning will be issued by the MOVEZ to the gateway twice via Lifeline group. First report will be issued
when battery level goes below 20% and second report will be issued when battery level goes below 10%.
Note: Along with every low battery warning notification MOVEZ also sends current battery report.
20
LED Indications main device
Red LED
Green LED
Meaning
OFF
Blink fast
Device in calibration mode
Blink fast
Blink fast
Device can enter learn mode
ON
ON
Device can do force reset operation
OFF
Blink 2 times
at power ON
Device inclusion completed. At bootup this blink indicate that the device is included
Blink 2 times
at power ON
OFF
Device exclusion completed or reset operation is successful. At bootup this blink indicate
that the device is not included
Blink 1 time
OFF
Too low power to star motor, further execution of position command is stopped
Blink 2 times
OFF
New position command received while still executing another command, motor will stop
Blink 3 times
OFF
Motor stall protection stop
Blink 4 times
OFF
Wall safety switch in wrong position and motor will stop
Table 8