7. RS232 output

The equipment has an RS232   data output in the control panel that can 
be used to register measurements in a serial printer or data collector. The 
outputs are the following ones:  

Pin 2: Rx ; Pin 3: Tx ; Pin 5: Gnd; 
Rate: 4800 bps 
8 bits - no parity - 1 stop bit (8,n,1) 

Note: In order to assure the compatibility with most printers available in 
the market, the resistance units are shown with the following symbols: 

uR = micro-ohm 
mR = milli-ohm 
R = ohm 

8. Cleaning

The panel, terminals and connectors of the equipment must stay dry and 
clean.  Cleaning  should  be  made  using  a  wet  cloth  in  water  and  a  soft 
detergent or  isopropyl alcohol  (be sure  that  the  products  to  be used  for 
cleaning does not affect plastic). 

9.

 Replacement fuse

To check the instrument fuse  , remove it with a screw driver. If the fuse 
is ruptured replace it by another with the following specifications: 

Fuse Schurter, model SPT 5x20 (Time-lag) 5A/250V. High breaking capacity. 

Summary of Contents for MPK254

Page 1: ...Formato 137mm x 190mm P 17 P 03 Manual de uso Micro ohm metro digital Digital micro ohmmeter User guide www tentech com...

Page 2: ...3 MPK 254 Digital micro ohmmeter User s guide GF 2045 2016 TENTECH All rights reserved...

Page 3: ...ing out the Control Panel in order to have an access to the internal parts may be dangerous as there are high voltages inside capable of causing fatal accidents Cleaning of this instrument should be c...

Page 4: ...e 6 2 Control panel 7 3 Power supply 8 3 1 Battery condition 8 3 2 Battery charger 8 4 Measurement 9 5 Messages 10 6 Some notes about accuracy 12 7 RS232 output 13 8 Cleaning 13 9 Replacement fuse 13...

Page 5: ...l method Digital reading alphanumeric display Up to 4 digits readings Powered by rechargeable battery 1 resolution 200 maximum reading 1 1 Operating principle This device uses the Kelvin Bridge archit...

Page 6: ...P Potential terminal P Current terminal C RS232 data output Alphanumeric display Shows both the measured resistance value and messages to the operator Start key Stop key Hold key It retains the last...

Page 7: ...AT message notifying that the charge level is low After a few minutes the measurement will be automatically interrupted in order to preserve the battery from a deep discharge that is prejudicial for i...

Page 8: ...t to be used 3 Switch the equipment On using the On Off 4 The PRESS START message will appear showing that measurement can be started Press the Start key Depending on the position of the test current...

Page 9: ...ll be released 9 Press the Stop key in order to finish the measurement Do not turn Off the equipment without pressing the Stop key before 10 Finally when finishing measurements turn the equipment Off...

Page 10: ...y cause a difficult circulation of test current If this message keeps on being displayed please check that the current cables are connected appropriately OVERRANGE It indicates that the measured resis...

Page 11: ...offset Thus it is not necessary to carry out measurements by reversing the polarity in order to compute the average value Nevertheless if the operator suspect that there is a difference of temperatur...

Page 12: ...stance units are shown with the following symbols uR micro ohm mR milli ohm R ohm 8 Cleaning The panel terminals and connectors of the equipment must stay dry and clean Cleaning should be made using a...

Page 13: ...tal direct reading of very low resistances in the alphanumerical display with up to 4 digits Very fast and accurate measurements Serial data output RS232 4800 bps Suitable for data collection in an ex...

Page 14: ...5 Dimensions 378 x 308 x 175 mm Accessories 2 Combined current and potential leads 1 8 m 1 Communication cable RS232 1 Power cord 1 User guide 1 Carrying bag Subject to technical change without notice...

Page 15: ...TENTECH option to free of charge repair or replacement of the defective product within the warranty period or to refund of the purchase price Any costs for transportation to manufactures facility is...

Page 16: ...17 MPK 254 Micro ohm metro digital Manual de uso 2016 TENTECH Todos los derechos reservados...

Page 17: ...o Retirar la tapa para acceder a su interior es peligroso porque existen tensiones elevadas capaces de provocar accidentes fatales La limpieza de este instrumento se debe realizar empleando un l quido...

Page 18: ...el 21 3 Alimentaci n 22 3 1 Estado de carga de la bater a 22 3 2 Cargador de bater a 22 4 Operando el equipo 23 5 Mensajes del display 25 6 Consideraciones acerca de la exactitud 26 7 Salida RS232 26...

Page 19: ...cesador Utiliza el m todo de los 4 terminales Lectura digital en display alfanum rico Indicaci n de hasta 4 d gitos Bater a recargable Resoluci n de 1 Lectura m xima de 200 Salida de datos RS232 1 1 P...

Page 20: ...de potencial P Borne negativo de corriente C Salida RS232 Display alfanum rico indicada el valor de resistencia bajo ensayo y avisos al usuario Start Tecla de inicio del ensayo Stop Tecla para finaliz...

Page 21: ...be por lo tanto ser cargada 3 2 Cargador de bater a Este equipo posee incorporado un circuito inteligente que controla la carga da bater a Para cargar la bater a siga el siguiente procedimiento Verifi...

Page 22: ...dici n con la llave del selector de rangos 5 4 3 2 1 6 7 8 9 R Los terminales cocodrilo en el dibujo son meramente ilustrativos 2 Encienda el equipo con la llave On Off 3 El display del equipo exhibir...

Page 23: ...nte provista por el equipo siempre que la misma sea superior al 80 del valor nominal de la escala 7 Completado este proceso el display indicar el valor de resistencia medido 8 La unidad de la resisten...

Page 24: ...el control test current en sentido horario para aumentar a corriente Si bien la medici n es viable con corrientes a partir del 10 de la corriente nominal seleccionada la exactitud especificada se obti...

Page 25: ...est siendo medida El valor a ser registrado ser el promedio entre los valores con corriente en un sentido y otro corriente directa e inversa El MPK 254 posee un sistema de auto compensaci n que elimin...

Page 26: ...izarse un destornillador de peque o porte y girar la tapa del porta fusible aproximadamente un cuarto de vuelta en sentido antihorario hasta sentir que est destrabado y que el resorte interno empuja h...

Page 27: ...tos Prestaciones avanzadas Lectura digital directa de los valores de resistencia medidos en el visor alfanum rico con hasta 4 d gitos Las mediciones se obtienen r pidamente y con gran exactitud Salida...

Page 28: ...accesorios Dimensiones 378 x 308 x 175 mm Accesorios 2 Puntas de prueba combinada corriente y potencial 1 8 m 1 Cable de comunicaci n RS232 1 Cable de alimentaci n 1 Manual de operaci n 1 Bolsa trans...

Page 29: ...arant a es de seis meses La obligaci n de TENTECH est limitada a alguna de las siguientes acciones a criterio exclusivo del fabricante la reparaci n sin cargo del producto o su sustituci n gratuita o...

Reviews: