background image

 

________________________________________________________________________________________________________________________________

 

TensioMed®

 

TensioDay

 

Plus™

 

5

 

Copyright

 

©

 

2011

 

TensioMed

 

Ltd.,

 

Budapest,

 

Hungary.

 

All

 

rights

 

reserved.

 

Under

 

the

 

copyright

 

laws,

 

this

 

manual

 

cannot

 

be

 

reproduced

 

in

 

any

 

form

 

without

 

prior

 

written

 

permission

 

of

 

TensioMed

 

Ltd.

 

 

Every

 

effort

 

has

 

been

 

made

 

to

 

ensure

 

that

 

the

 

information

 

in

 

this

 

manual

 

is

 

accurate.

 

Succeeding

 

models

 

and

 

manuals

 

are

 

subject

 

to

 

change

 

without

 

notice.

  

 

TensioMed

 

is

 

not

 

responsible

 

for

 

printing

 

or

 

clerical

 

errors.

 

 

This

 

Manual

 

is

 

produced

 

on

 

the

 

assumption

 

that

 

the

 

operator

 

is

 

an

 

experienced

 

user

 

of

 

the

 

Windows

 

XP/Vista/7/8

 

operating

 

Systems.

 

If

 

the

 

operator

 

is

 

not

 

familiar

 

with

 

Windows

 

operations,

 

please

 

refer

 

to

 

the

 

On

line

 

Help

 

of

 

Windows

 

or

 

the

 

Windows

 

User

 

Manual.

 

 

TensioMed®

 

TensioDay

 

Plus™

 

is

 

an

 

unregistered

 

trademark

 

of

 

TensioMed

 

Ltd.

 

Other

 

company

 

and

 

product

 

names

 

mentioned

 

herein

 

may

 

be

 

trademarks

 

of

 

their

 

respective

 

companies.

 

 
 

1.1.

 

Contents

 

of

 

the

 

manual

 

 

This

 

manual

 

helps

 

you

 

in

 

setting

 

up

 

and

 

starting

 

to

 

use

 

the

 

TensioMed®

 

TensioDay

 

Plus™

 

device.

 

 

!

 

Attention!

 

Before

 

first

 

use,

 

please

 

read

 

and

 

understand

 

this

 

document

 

carefully.

 

 

1.2.

 

Supplementary

 

Information

 

and

 

Helpful

 

Hints

 

 

This

 

device

 

does

 

not

 

produce

 

electromagnetic

 

disturbances

 

during

 

its

 

operation

 

and

 

its

 

immunity

 

to

 

the

 

environmental

 

disturbances

 

is

 

also

 

good.

 

The

 

download

 

of

 

the

 

measured

 

data

 

to

 

the

 

physician's

 

PC

 

is

 

done

 

by

 

Bluetooth

 

communication.

 

The

 

electromagnetic

 

compatibility

 

between

 

the

 

device

 

and

 

the

 

PC

 

is

 

guaranteed.

 

EMC

 

classification:

 

A.

 

 

Regular

 

service

 

is

 

recommended

 

by

 

an

 

approved

 

agent

 

at

 

least

 

every

 

two

 

years

 

to

 

maintain

 

optimum

 

performance

 

and

 

accuracy.

 

 

The

 

cuff

 

and

 

the

 

Device

 

itself

 

can

 

be

 

cleaned

 

with

 

a

 

wet

 

cloth

 

by

 

making

 

sure

 

that

 

no

 

liquid

 

enter

 

into

 

the

 

Device

 

or

 

the

 

cuff.

 

 

The

 

handling,

 

storage,

 

wrapping,

 

substance

conservation

 

and

 

transportation

 

of

 

the

 

producer's

 

devices

 

are

 

defined

 

in

 

accordance

 

with

 

the

 

general

 

Quality

 

Control

 

Requirements.

 

 

Summary of Contents for tensioday plus

Page 1: ...blood pressure monitor featuring central blood pressure measurement With wireless communication Bluetooth Please read the user s manual carefully before the first use TensioMed TensioDay Plus 5 02 v2...

Page 2: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 2...

Page 3: ...s device 8 2 1 Explanation of symbols 8 2 2 Accessories 10 2 3 Installing the Device 10 2 4 Operations Instructions 11 2 4 1 Functions of the button on the device 12 2 4 1 1 One short push of the butt...

Page 4: ...lood pressure readings are loaded via bluetooth communication from and to the physician s PC respectively Automatic measurements can be set for up to 48 hours with frequencies ranging from 10 to 90 mi...

Page 5: ...company and product names mentioned herein may be trademarks of their respective companies 1 1 Contents of the manual This manual helps you in setting up and starting to use the TensioMed TensioDay Pl...

Page 6: ...1182 Hungary Phone 36 1 433 1700 433 1701 Fax 36 1 433 1709 Web www tensiomed com E mail info tensiomed com 1 4 General Information warnings and precautions We strongly suggest that you carefully stud...

Page 7: ...unit with special care Children should not use the device on their own Do not remove the outer cover of the device The TensioMed TensioDay Plus 24 hour BPM device is sophisticated multipurpose softwar...

Page 8: ...flation continues above this value or the pressurization lasts too long unplug the pneumatic connector of the cuff from the device and remove the cuff from the subject Do not use the device on an arm...

Page 9: ...anual 12 Certification mark guaranteeing that the apparatus complies with the prescriptions and requirements of the European Union 13 Serial number 14 Operating ambient temperature range 15 Year of th...

Page 10: ...ircumference range Cuff S 20 8 cm 41 5 10 cm 20 24 cm Cuff M 23 11 5 cm 57 14 cm 24 32 cm Cuff L 28 x 11 5 cm 64 x 14 cm 32 38 cm The manufacturer of the cuffs ERKA Kallmeyer Medizintechnik GmbH Co KG...

Page 11: ...ay The batteries and charging appliances have their own Instructions for use we suggest you study them and follow manufacturers guidelines In case you do not have a Bluetooth communication adapter or...

Page 12: ...Day Plus is ready for operation D 09 39 2 4 1 1 One short push of the button starts a manual measurement During the ambulatory measuring mode there might be a need for manual measurements for example...

Page 13: ...s ready for measurement for manual and programmed mode OFF 2 4 1 2 Two short pushes on the button Pill allows the patient to keep his electronic diary concerning taking his antihypertensive medication...

Page 14: ...nloads all the stored data to the physician s PC via Bluetooth communication The information loaded consists of the systolic and diastolic blood pressure values mmHg the pulse rate per minute the dist...

Page 15: ...the patient s blood pressure within the measuring time 3 The measurement was interrupted due to the weakness of the battery 31 The cuff is not connected to the device 32 The cuff tube is broken or so...

Page 16: ...ree ambulation to avoid skin irritation a thin shirt might be used below the cuff the tube of the cuff should be inserted into the air connector of the device see figure 1 Attention Please take care o...

Page 17: ...asurement method Oscillometric Data Storage Max 1000 measurements Blood Pressure measurements range 30 280 mmHg Static accuracy 3 mmHg or 2 of the measured value Measuring accuracy Systolic 94 out of...

Page 18: ...ice is intended for use in the electromagnetic environment specified below The customer or the user of the TensioMed TensioDay Plus TD3 device should assure that it is used in such an environment Immu...

Page 19: ...the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the TensioMed TensioDay Plus TD...

Page 20: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 20...

Page 21: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 21...

Page 22: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 22...

Page 23: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 23...

Page 24: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 24...

Reviews: