background image

 

________________________________________________________________________________________________________________________________

 

TensioMed®

 

TensioDay

 

Plus™

 

13

 

The

 

deflation

 

of

 

the

 

cuff

 

is

 

shown

 

by

 

the

 

adjacent

 

figure

 

X

_

       

69

 

After

 

this

 

process

 

the

 

device

 

shows

 

the

 

systolic

 

and

 

diastolic

 

BP

 

values

  

Then

 

the

 

pulse

 

rate

 

is

 

shown

 

on

 

the

 

display,

 

and

 

the

 

device

 

stores

 

all

 

the

 

measured

 

data,

 

including

 

the

 

date

 

and

 

exact

 

time.

 

 

128/96

PUL 68

 

At

 

any

 

time

 

during

 

a

 

reading

 

the

 

patient

 

can

 

terminate

 

a

 

reading

 

by

 

pressing

 

once

 

the

 

single

 

button.

 

A

 

termination

 

symbol

 

will

 

appear

 

on

 

the

 

display

 

for

 

10

 

sec

 

(see

 

adjacent

 

figure).

 

Then

 

the

 

time

 

will

 

appear

 

and

 

the

 

units

 

ready

 

for

 

measurement,

 

for

 

manual

 

and

 

programmed

 

mode.

 

 

OFF

 

 
 

2.4.1.2.

 

Two

 

short

 

pushes

 

on

 

the

 

button

(Pill):

 

allows

 

the

 

patient

 

to

 

keep

 

his

 

"electronic

 

diary"

 

concerning

 

taking

 

his

 

(antihypertensive)

 

medication.

 

After

 

taking

 

his

 

medicine,

 

two

 

short

 

pushes

 

on

 

the

 

button

 

stores

 

the

 

date

 

and

 

time

 

in

 

the

 

memory.

 

During

 

a

 

day,

 

it

 

is

 

possible

 

to

 

store

 

additional

 

pill

 

consumptions.

 

By

 

downloading

 

all

 

the

 

data

 

from

 

the

 

device

 

to

 

the

 

physician's

 

PC,

 

he

 

will

 

be

 

able

 

to

 

monitor

 

the

 

medication

 

intake

 

and

 

therefore

 

the

 

compliance

 

of

 

the

 

patient.

 

 

Pill

 

If

 

the

 

memory

 

of

 

the

 

device

 

is

 

full,

 

this

 

will

 

appear

 

on

 

the

 

display.

 

 
 

FULL

 

2.4.1.3.

 

Three

 

short

 

pushes

 

on

 

the

 

button

allows

 

the

 

patient

 

to

 

indicate

 

the

 

time

 

of

 

going

 

to

 

bed

 

and

 

waking

 

up

 

in

 

the

 

tabulated

 

list

 

of

 

measurements.

 

The

 

device

 

indicates

 

the

 

waking

 

up

 

by

 

a

 

D

 

and

 

by

 

an

 

N

 

when

 

the

 

patient

 

goes

 

to

 

bed.

 

 

D  09-39
N  20-39

 

 
 
 
 
 
 
 

Summary of Contents for tensioday plus

Page 1: ...blood pressure monitor featuring central blood pressure measurement With wireless communication Bluetooth Please read the user s manual carefully before the first use TensioMed TensioDay Plus 5 02 v2...

Page 2: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 2...

Page 3: ...s device 8 2 1 Explanation of symbols 8 2 2 Accessories 10 2 3 Installing the Device 10 2 4 Operations Instructions 11 2 4 1 Functions of the button on the device 12 2 4 1 1 One short push of the butt...

Page 4: ...lood pressure readings are loaded via bluetooth communication from and to the physician s PC respectively Automatic measurements can be set for up to 48 hours with frequencies ranging from 10 to 90 mi...

Page 5: ...company and product names mentioned herein may be trademarks of their respective companies 1 1 Contents of the manual This manual helps you in setting up and starting to use the TensioMed TensioDay Pl...

Page 6: ...1182 Hungary Phone 36 1 433 1700 433 1701 Fax 36 1 433 1709 Web www tensiomed com E mail info tensiomed com 1 4 General Information warnings and precautions We strongly suggest that you carefully stud...

Page 7: ...unit with special care Children should not use the device on their own Do not remove the outer cover of the device The TensioMed TensioDay Plus 24 hour BPM device is sophisticated multipurpose softwar...

Page 8: ...flation continues above this value or the pressurization lasts too long unplug the pneumatic connector of the cuff from the device and remove the cuff from the subject Do not use the device on an arm...

Page 9: ...anual 12 Certification mark guaranteeing that the apparatus complies with the prescriptions and requirements of the European Union 13 Serial number 14 Operating ambient temperature range 15 Year of th...

Page 10: ...ircumference range Cuff S 20 8 cm 41 5 10 cm 20 24 cm Cuff M 23 11 5 cm 57 14 cm 24 32 cm Cuff L 28 x 11 5 cm 64 x 14 cm 32 38 cm The manufacturer of the cuffs ERKA Kallmeyer Medizintechnik GmbH Co KG...

Page 11: ...ay The batteries and charging appliances have their own Instructions for use we suggest you study them and follow manufacturers guidelines In case you do not have a Bluetooth communication adapter or...

Page 12: ...Day Plus is ready for operation D 09 39 2 4 1 1 One short push of the button starts a manual measurement During the ambulatory measuring mode there might be a need for manual measurements for example...

Page 13: ...s ready for measurement for manual and programmed mode OFF 2 4 1 2 Two short pushes on the button Pill allows the patient to keep his electronic diary concerning taking his antihypertensive medication...

Page 14: ...nloads all the stored data to the physician s PC via Bluetooth communication The information loaded consists of the systolic and diastolic blood pressure values mmHg the pulse rate per minute the dist...

Page 15: ...the patient s blood pressure within the measuring time 3 The measurement was interrupted due to the weakness of the battery 31 The cuff is not connected to the device 32 The cuff tube is broken or so...

Page 16: ...ree ambulation to avoid skin irritation a thin shirt might be used below the cuff the tube of the cuff should be inserted into the air connector of the device see figure 1 Attention Please take care o...

Page 17: ...asurement method Oscillometric Data Storage Max 1000 measurements Blood Pressure measurements range 30 280 mmHg Static accuracy 3 mmHg or 2 of the measured value Measuring accuracy Systolic 94 out of...

Page 18: ...ice is intended for use in the electromagnetic environment specified below The customer or the user of the TensioMed TensioDay Plus TD3 device should assure that it is used in such an environment Immu...

Page 19: ...the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the TensioMed TensioDay Plus TD...

Page 20: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 20...

Page 21: ...________________________________________________________________________________________________________________________________ TensioMed TensioDay Plus 21...