background image

2

Use shielded and twisted signal cables and connect shield to ground. Keep all signal cables away from circuit breakers,

inductive loads, device/cables emitting electrical noise and power cables.

Take precautions agains environmental conditions like humidity, vibration, pollution and high/low temperature during 

installation.

Use fuse (F250mA 250VAC) on mains/supply input of the device. Use appropriate cables for supply connections. 

Apply safety regulations during installation.

Prefer to use (Inpt = Phs1) option for encoders, select (Freq = 20) to count mechanical switch ON-OFF pulses, select
the minimum input frequency option that suits your application.

For Inpt = 1u2u, 1u2d, Phs2; input signal frequency shall be at most ½ of the selected input frequency option if both

inputs are used. And for Inpt = Phs4; input signal frequency shall be at most 1/4 of the selected input frequency option

if both inputs are used.

Warning:

!

Connect SS Out return pin directly to GND.
Use free-wheeling diode to protect SS Out.
To select PNP option; connect “npn select” to “+12V”.

Notes:

Connection

N

L1

2A

Load

DS-48

3

2

1

4

5

10

9

8

11

12

13

14

1

0

0

..2

4

0

 V

A

C

5

0

/6

0

H

z

 6

V

A

no

Out

nc

+12V

 50mA

npn

select

Cp1

input

Cp2

input

Reset

SS Out

GND

+

30Vdc

(Max)

SSR

Reviews: