Specifications 

 

 

Amplifier type

Mono Power amplifier

Rated power: 4, 8, 16 Ohms

60, 75, 75 W

Load impedance

4 – 16 Ohms

Recommended load

8 Ohms

Dynamic power: 8 Ohms

225 W

Pure Class A power: 8 Ohms

40 W

Power Bandwidth  (-3 dB)

2  to 160 000 Hz

Harmonic dist noise 

less than 0,5%

Intermodulation distortion 

less than 0,5%

Signal to noise ratio

100 dB A weighted

Input impedance

40 K Ohms

Output impedance

0.4 Ohms

Input sensitivity

350 mV bal., 700 mV RCA.

Output stage power transformer

750 VA

Driver stage power transformer

750 VA

Input

RCA or XLR

Multi function meter

analog 1.5 %

Input tubes                                                                     2 x 12AX7A, 2 x 6H6P , 2 x 6H30P

Output tubes 

4 x 6C33C-B

Soft start / Mute

1 minute

Maximum power consumption

730 W

Supply voltage

100, 120, 220 or 240

AC mains input                                                               15 / 6A IEC detachable power cord

Dimensions  ( w x d x h )                                                 17.25 x 23 x 11 inches

Weight per unit

 71 pounds

 
 
 

 
 
 

 

Summary of Contents for 75Wi

Page 1: ...Tenor Audio 75Wi Owner s manual Version 1 0...

Page 2: ...Table of contents 1 Safety Instructions 2 Introduction 3 Unpacking Installation 4 Operation Hook up 5 Bias DC Balance adjustments 6 Specifications 7 Warranty...

Page 3: ...enclosure voltage that may be sufficient to constitute a risk of shock This triangle which appears on your component alerts you to important operating and maintenance instructions in this accompanyin...

Page 4: ...o unheard levels of musical refinement Dynamics All our amplifiers have an impressive dynamic power reserve Thus they can momentarily quadruple the rated output power without any perceived signal degr...

Page 5: ...vacuum tubes 4 x 12AX7A ECC83 vacuum tubes 2 Power cords 1 Adjustment screwdriver 1 Hex key 1 Owners manual 2 Spare fan air filters 2 Spare mains AC fuses 2 Spare 5A 5mm fuses Installation The amplif...

Page 6: ...plifier white RCA connector that will drive the left loudspeaker and the right channel output of the source device to the corresponding input on the right amplifier red RCA connector driving the right...

Page 7: ...ter to read 300mA on the meter The normal operating bias current for each 6C33C B power tube is 300mA the meter range is 0 to 500mA 3 Set the bias rotary selector to successively V8 V9 V10 and perform...

Page 8: ...noise ratio 100 dB A weighted Input impedance 40 K Ohms Output impedance 0 4 Ohms Input sensitivity 350 mV bal 700 mV RCA Output stage power transformer 750 VA Driver stage power transformer 750 VA I...

Page 9: ...ranteed for a period of three months after purchase Should the unit become defective during the warranty period Tenor Audio will elect to repair or replace the unit free of charge Tenor Audio will NOT...

Reviews: