Safety Instructions 

 
 

Save these instructions for later use. Follow all instructions and warnings marked on the unit. 
 
Always use with the correct line voltage.  Refer to the manufacturer's operating instructions for power requirements.  
Be advised that different operating voltages may require the use of a different line cord and/or attachment plug. 
Do not install  the unit in an unventilated rack, or directly  above heat producing equipment.   Observe the maximum 
ambient operating temperature listed in the product specification. 
Slots  and  opening  on  the  case  are  provided  for  ventilation;  to  ensure  reliable  operation  and  prevent  it  from 
overheating,  these  openings  must  not  be  blocked  or  covered.    Never  push  objects  of  any  kind  through  any  of  the 
ventilation slots.  Never spill a liquid of any kind on the unit. 
Never attach audio power amplifier outputs directly to any of the unit's connectors. 
To prevent shock or fire hazard, do not expose the unit to rain or moisture, or operate it where it will be exposed to 
water or excessive dampness. Do not remove vacuum tubes without unplugging power cord from AC mains.  
 
Do not attempt to operate the unit if it has been dropped, damaged, exposed to liquids, or if it exhibits a distinct change 
in performance indicating the need for service. 
 

Caution! 
Only  qualified  service  personnel  should  open  this  unit.    Removing  covers  will  expose  you  to  hazardous 
voltages. 

 

This triangle, which appears on your component, 

alerts  you  to  the  presence  of  uninsulated 
dangerous  voltage  inside  the  enclosure...voltage 
that may be sufficient to constitute a risk of shock. 

 

This  triangle,  which  appears  on  your 

component, alerts you to important operating 
and  maintenance  instructions  in  this 
accompanying literature. 

 
 
Adhere to all warnings on the unit and in the operating instructions. 
Take precautions not to defeat the grounding or polarization of the unit's power cord. 
Do not overload wall outlet, extension cords or integral convenience receptacles, as this can result in a risk of fire or 
electrical shock. 
Route power supply cords so that they are not likely to be walked on or pinched by items placed on or against them, 
paying particular attention to cords at plugs, convenience receptacles, and the point at which they exit from the unit. 
 
The unit should be cleaned only as recommended by the manufacturer. 
 
 
 

 

 

Outdoor Antenna Grounding

 

 

If 

an outside antenna is connected to the playback system, be sure the 

antenna  system  is  grounded  so  as  to  provide  some  protection  against 
voltage surges and built-up static charges.  Section 810 of the National 
Electrical  Code,  ANSI/NFPA  No.  70-1984,  provides  information  with 
respect  to  proper  grounding  of  the  mast  and  supporting  structure, 
grounding  of  the  lead-in  wire  to  an  antenna-discharge  unit,  size  of 
grounding conductors, location of antenna-discharge unit, connection to 
grounding  electrodes,  and  requirements  for  the  grounding  electrode.  
See figure. 

 
Note  to  CATV  installers:  Article  820-40  of  the  NEC  provides  guidelines  for  proper  grounding  and,  in  particular, 
specifies that  the cable ground shall be connected  to  the grounding system of the building, as close to the  point  of 
cable entry as practical. 
 
Power Lines: An outside antenna should be located away from power lines. 

Summary of Contents for 75Wi

Page 1: ...Tenor Audio 75Wi Owner s manual Version 1 0...

Page 2: ...Table of contents 1 Safety Instructions 2 Introduction 3 Unpacking Installation 4 Operation Hook up 5 Bias DC Balance adjustments 6 Specifications 7 Warranty...

Page 3: ...enclosure voltage that may be sufficient to constitute a risk of shock This triangle which appears on your component alerts you to important operating and maintenance instructions in this accompanyin...

Page 4: ...o unheard levels of musical refinement Dynamics All our amplifiers have an impressive dynamic power reserve Thus they can momentarily quadruple the rated output power without any perceived signal degr...

Page 5: ...vacuum tubes 4 x 12AX7A ECC83 vacuum tubes 2 Power cords 1 Adjustment screwdriver 1 Hex key 1 Owners manual 2 Spare fan air filters 2 Spare mains AC fuses 2 Spare 5A 5mm fuses Installation The amplif...

Page 6: ...plifier white RCA connector that will drive the left loudspeaker and the right channel output of the source device to the corresponding input on the right amplifier red RCA connector driving the right...

Page 7: ...ter to read 300mA on the meter The normal operating bias current for each 6C33C B power tube is 300mA the meter range is 0 to 500mA 3 Set the bias rotary selector to successively V8 V9 V10 and perform...

Page 8: ...noise ratio 100 dB A weighted Input impedance 40 K Ohms Output impedance 0 4 Ohms Input sensitivity 350 mV bal 700 mV RCA Output stage power transformer 750 VA Driver stage power transformer 750 VA I...

Page 9: ...ranteed for a period of three months after purchase Should the unit become defective during the warranty period Tenor Audio will elect to repair or replace the unit free of charge Tenor Audio will NOT...