Tennant V-WA-76 Operator'S Manual Download Page 7

7

EXHAUST FILTER REPLACEMENT

1.  Turn off and unplug vacuum cleaner.
2.  Carefully turn machine on its side and remove exhaust cover from   
  bottom of machine.
3.  Remove the two nuts holding filter onto machine.
4.  Replace filter in proper position and tighten nuts.
5.  Reinstall exhaust cover.
*Replace exhaust filter every 6 months.

BELT ADJUSTMENT AND REPLACEMENT

1.  Turn off and unplug vacuum cleaner. 
2.  Remove belt cover on left side of machine.
3.  Loosen the motor belt adjusting screws on motor bracket.
4.  Remove belt.
5.  Install new belt and reposition motor to eliminate excess slack.
6.  Once proper tension is set, tighten motor adjusting screws.
7.  Replace belt cover on side of machine.

VACUUM MOTOR FILTERS

ELECTRICAL DIAGRAM

VACUUM MOTOR FILTERS

1.  Turn off and unplug vacuum cleaner. 
2.  Position the handle in normal operating position.
3.  Open Wide Area Vacuum lid and rest it on the handle.
4.  Remove clamp with a screwdriver to gain access to filter
5.  Remove plastic cap covering the motor
6.  Remove plastic retainer in cap
7.  Replace filters in their original positions.
8.  Reinstall plastic retainer in cap
9.  Reinstall cap onto motors
10. Reinstall clamp.
*Replace the vacuum motor filters every 6 months.

 Model

 V-WA-76

Voltage / Frequency

220-240 V / 50-60 Hz

Vacuum motor rating

1976W / 8 A

Brush Motor rating

1/4 hp / 2 A

Total power consumption`

10 A

Bag capacity – dry

43 L

Airflow

384 m3/h

Vacuum – water lift at sealed orifice

1804 mm

Filtration - HEPA

99.97% @0.3 micron

Vibration at controls

< 2.5 m/s2

Brush width

762 mm

Cable length

23 m

Weight (including cord)

33.6 kg 

Noise level

69.9 dB(A)

Construction class

I

Protection

IP20

Machine dimensions

Folded: 838 mm X 787 mm X 483 mm

Operating Position:

838 mm X 787 mm X 991 mm

MACHINE SPECIFICATIONS

ENGLISH

Summary of Contents for V-WA-76

Page 1: ...rt No 1070016 V WA 76 220 240V 50 60 Hz V WA 76 Wide Area Vacuum Cleaner Operator and Parts Manual IMPORTANT Read these Instructions Carefully and Retain for Future Use EN 9009405 00 01 2013 www tenna...

Page 2: ...erial number of this product may be found on the back side of the unit You should complete the enclosed warranty card and mail it back to us as soon as possible for your protection Also note the model...

Page 3: ...from heated surfaces 9 Do not unplug by pulling on cord 10 Turn off all controls before unplugging 11 Do not attempt to service the machine while cord is plugged in 12 Do not handle plug or machine w...

Page 4: ...or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance If it will not fit the outlet have a proper outlet installed by...

Page 5: ...9009085 1 per package Genuine OEM Vacuum Filters Part 9009078 1 per package Exhaust Filters MACHINE CARTON CONTENTS NOTE Each machine is equipped with one extra vacuum bag On Off Switch Handle Adjust...

Page 6: ...nual circuit breakers a 10 amp breaker for the vacuum motor and a 1 6 amp breaker for the brush motor If the machine does not turn on you will need to check the circuit breakers To reset circuit break...

Page 7: ...um cleaner 2 Position the handle in normal operating position 3 Open Wide Area Vacuum lid and rest it on the handle 4 Remove clamp with a screwdriver to gain access to filter 5 Remove plastic cap cove...

Page 8: ...8 V WA 76 PARTS LIST 14 13 15 16 17 18 19 20 22 21 23 24 25 27 28 34 29 31 32 32 33 36 35 26 30 5 2 1 3 4 6 7 8 10 9 11 37 8 38 39 39 43 41 40 42 12...

Page 9: ...y 24 9009061 BRUSH ASSY FR includes 2 gaskets 6 1 4 20 x 1 2 screws 1 25 9009055 SHROUD AIR INTK FR includes 4 16 x 3 4 screws 2 3 16 x 1 2 x 14 75 gasket 1 25 gasket 1 26 9009004 BAG CLOTH FR 1 27 90...

Page 10: ......