![Tennant V-WA-76 Operator'S Manual Download Page 7](http://html1.mh-extra.com/html/tennant/v-wa-76/v-wa-76_operators-manual_1087389007.webp)
7
EXHAUST FILTER REPLACEMENT
1. Turn off and unplug vacuum cleaner.
2. Carefully turn machine on its side and remove exhaust cover from
bottom of machine.
3. Remove the two nuts holding filter onto machine.
4. Replace filter in proper position and tighten nuts.
5. Reinstall exhaust cover.
*Replace exhaust filter every 6 months.
BELT ADJUSTMENT AND REPLACEMENT
1. Turn off and unplug vacuum cleaner.
2. Remove belt cover on left side of machine.
3. Loosen the motor belt adjusting screws on motor bracket.
4. Remove belt.
5. Install new belt and reposition motor to eliminate excess slack.
6. Once proper tension is set, tighten motor adjusting screws.
7. Replace belt cover on side of machine.
VACUUM MOTOR FILTERS
ELECTRICAL DIAGRAM
VACUUM MOTOR FILTERS
1. Turn off and unplug vacuum cleaner.
2. Position the handle in normal operating position.
3. Open Wide Area Vacuum lid and rest it on the handle.
4. Remove clamp with a screwdriver to gain access to filter
5. Remove plastic cap covering the motor
6. Remove plastic retainer in cap
7. Replace filters in their original positions.
8. Reinstall plastic retainer in cap
9. Reinstall cap onto motors
10. Reinstall clamp.
*Replace the vacuum motor filters every 6 months.
Model
V-WA-76
Voltage / Frequency
220-240 V / 50-60 Hz
Vacuum motor rating
1976W / 8 A
Brush Motor rating
1/4 hp / 2 A
Total power consumption`
10 A
Bag capacity – dry
43 L
Airflow
384 m3/h
Vacuum – water lift at sealed orifice
1804 mm
Filtration - HEPA
99.97% @0.3 micron
Vibration at controls
< 2.5 m/s2
Brush width
762 mm
Cable length
23 m
Weight (including cord)
33.6 kg
Noise level
69.9 dB(A)
Construction class
I
Protection
IP20
Machine dimensions
Folded: 838 mm X 787 mm X 483 mm
Operating Position:
838 mm X 787 mm X 991 mm