Tennant V-WA-76 Operator'S Manual Download Page 6

6

HANDLE ADJUSTMENT

1.  Loosen handle adjustment lock lever and adjust handle to comfortable  
  operation height
2.  Tighten lever to lock handle in place.

BAG INSTALLATION

1.  Position the handle in normal operating position.
2.  Open bag compartment lid and rest it on the handle.
3.  Unzip cloth bag and install paper bag inside.
4.  Attach both bag openings together onto vacuum intake housing. 
5.  Make sure bag is properly positioned inside machine housing.
6.  Completely close zipper on cloth bag and close lid of machine.

ATTENTION: Always use cloth and paper bags together.

BRUSH HEIGHT ADJUSTMENT

1.  This machine has 5 brush adjustment levels.
2.  To raise brush height level: lift up height adjustment pedal until  

 

  desired brush height is attained.
3.  To lower brush height level: push down on height adjustment pedal  
  until desired brush height is attained. 

OPERATION OF MACHINE

1.  Plug power cord into properly grounded power outlet.
2.  Push the on/off switch to the ON (I) position.
3.  To operate brush squeeze the brush start triggers.
4.  Push machine forward to begin cleaning.
5.  Adjust brush height for proper pick-up.

  

CIRCUIT BREAKER PROTECTION

Your new wide area vacuum comes equipped with two manual circuit 
breakers, a 10 amp breaker for the vacuum motor and a 1.6 amp breaker 
for the brush motor. If the machine does not turn on you will need to 
check the circuit breakers.

 

To reset circuit breakers:

 

1. Turn off and unplug the vacuum cleaner.

 

2. Check machine for the following:  

 

  Full bag, obstructions, clogged filters, clogged brush, brush 

 

  height set too low, etc.

 

3. Press the affected circuit breaker button to reset.

 

4. Resume operation 

If vacuum cleaner fails to turn on, contact a Tennant Authorized Service 
Center or Distributor.

FOR BEST PERFORMANCE

•  Keep machine and all accessories clean and in good operating 

condition.

•  Change vacuum bags and filters as recommended to maintain 

optimum cleaning efficiency.

•  Always use OEM bags, filters and parts, as use of other products 

may result in poor cleaning of filtration performance. OEM products 
are designed for maximum performance.

•  Have machine checked periodically by a Tennant Authorized Ser-

vice Center or Distributor.

•  Store machine carefully in a dry area.
•  For optimum cleaning performance and safety, follow your owner’s 

manual.

•  After each use, carefully wrap power cord around handle and check 

cord for wear or damage. If cord is damaged, have power cord 
replaced by a Tennant Authorized Service Center or Distributor im-
mediately.

MACHINE MAINTENANCE

 

CAUTION: Turn off and unplug the 

vacuum cleaner before performing  

maintenance.

ENGLISH

Summary of Contents for V-WA-76

Page 1: ...rt No 1070016 V WA 76 220 240V 50 60 Hz V WA 76 Wide Area Vacuum Cleaner Operator and Parts Manual IMPORTANT Read these Instructions Carefully and Retain for Future Use EN 9009405 00 01 2013 www tenna...

Page 2: ...erial number of this product may be found on the back side of the unit You should complete the enclosed warranty card and mail it back to us as soon as possible for your protection Also note the model...

Page 3: ...from heated surfaces 9 Do not unplug by pulling on cord 10 Turn off all controls before unplugging 11 Do not attempt to service the machine while cord is plugged in 12 Do not handle plug or machine w...

Page 4: ...or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance If it will not fit the outlet have a proper outlet installed by...

Page 5: ...9009085 1 per package Genuine OEM Vacuum Filters Part 9009078 1 per package Exhaust Filters MACHINE CARTON CONTENTS NOTE Each machine is equipped with one extra vacuum bag On Off Switch Handle Adjust...

Page 6: ...nual circuit breakers a 10 amp breaker for the vacuum motor and a 1 6 amp breaker for the brush motor If the machine does not turn on you will need to check the circuit breakers To reset circuit break...

Page 7: ...um cleaner 2 Position the handle in normal operating position 3 Open Wide Area Vacuum lid and rest it on the handle 4 Remove clamp with a screwdriver to gain access to filter 5 Remove plastic cap cove...

Page 8: ...8 V WA 76 PARTS LIST 14 13 15 16 17 18 19 20 22 21 23 24 25 27 28 34 29 31 32 32 33 36 35 26 30 5 2 1 3 4 6 7 8 10 9 11 37 8 38 39 39 43 41 40 42 12...

Page 9: ...y 24 9009061 BRUSH ASSY FR includes 2 gaskets 6 1 4 20 x 1 2 screws 1 25 9009055 SHROUD AIR INTK FR includes 4 16 x 3 4 screws 2 3 16 x 1 2 x 14 75 gasket 1 25 gasket 1 26 9009004 BAG CLOTH FR 1 27 90...

Page 10: ......

Reviews: