OPERATION
EN
9
BR--1200--NDC / BR--1600--NDC (04--10)
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
Motor does not operate.
Machine circuit breaker tripped.
(Spray buffing with the BR--1600--NDC
model is not recommended).
Determine cause and reset breaker on
machine. Wait 15 seconds before
restarting machine.
Building circuit breaker tripped.
Reset breaker and change to different
circuit.
Faulty power cord.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Faulty twist grip switch.
Contact Service Center.
Faulty Rectifier.
Contact Service Center.
Faulty Motor.
Contact Service Center.
Machine circuit breaker trips
continuously.
Soiled Pad.
Replace Pad.
Improper pad for application.
Change to proper pad.
Defective circuit breaker.
Contact Service Center.
Worn carbon brushes in motor.
Contact Service Center.
Pad spins slowly or not at all.
Loose drive belt.
Tighten drive belt.
Broken drive belt.
Replace drive belt.
SPECIFICATIONS
MODEL
BR--1200--NDC
BR--1600--NDC
WIDTH
20.75 in / 530 mm
20.75 in / 530 mm
HEIGHT
49 in / 1,240 mm
49 in / 1,240 mm
LENGTH
29.75 in / 760mm
29.75 in / 760mm
WEIGHT
68 lb / 31 kg
68 lb / 31 kg
DRIVE MOTOR
120 V, 1.5 hp, 15 A, 60 H
Z
120 V, 1.5 hp, 15 A, 60 H
Z
PAD/BRUSH SPEED
1,200 rpm
1,600 rpm
POWER CORD LENGTH
75 ft / 23 m Gauge 3 X 1.5 mm
75 ft / 23 m Gauge 3 X 1.5 mm
PAD DIAMETER
20 in / 510 mm
20 in / 510 mm
DECIBEL RATING AT
OPERATOR’S EAR, INDOORS ON TILE
FLOOR
70 dBA
70 dBA