OPERATION
Boss 2000E (08–03)
15
12. Begin prespraying, hold wand about one foot
above carpet. Use a sweeping pattern when
applying prespray solution. (Figure 28)
FIG. 28
13. Return prespray wand to holder.
14. Allow prespray solution to set for at least 5
minutes and no longer than 15 minutes before
operating machine.
15. Turn on ”VACUUM” switch.
16. Take floor tool and begin cleaning at top of area
and work backwards toward machine.
17. Place floor tool so bottom of glide plate or
stainless shoes are parallel to floor. Squeeze
trigger and apply downward pressure on floor tool
head and slowly pull tool backwards using both
hands. Release trigger 6 inches from end of stroke
(Figure 29).
FIG. 29
18. Push floor tool forward over same path with trigger
released when returning for next stroke. Continue
this pull and push method with a 2 to 4” overlap of
each stroke.
NOTE: For heavily soiled areas, repeat stroke or
change angle of stroke.
DRAINING AND RINSING TANKS
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine and unplug
cord from wall outlet.
DRAINING RECOVERY TANK
IMPORTANT: Recovery tank MUST be drained
every time solution tank runs dry.
ATTENTION: Do not allow foam to enter shut–off
float. Foam will damage vacuum motor and this
damage is not covered by warranty.
1.
Turn key off and unplug power cord.
2.
Raise brush.
3.
Transport machine to nearest floor sink or drain.
4.
Remove drain hose from holder, position hose
over floor drain and twist off drain hose plug to
drain (Figure 30).
FIG. 30
5.
Replace drain hose plug tightly.
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com