GROUND KIT, STATIC
KIT NO. 9002378
Page 1 of 3
Models: T7 / Speed Scrub Rider
9002379 Rev. 00 (02--06)
Tennant Company
Customer Service: (800) 553--8033 or (763) 513--2850
This kit is intended for machines manufacturered
before serial #10266229.
The purpose of this kit is to help prevent dam-
age to the newly installed circuit board.
P/N
DESCRIPTION
QTY.
41141
Washer, Lock, Int--Ext, 0.31 ZN
4
09010
Screw, Hex, M8x1.25X25 SS
1
1030479
Wire Assy, 12.0X.312X.312 Ring Term.
1
KIT CONTENTS
INSTALLATION INSTRUCTIONS:
Installation Time: 1 Hour
TOOLS REQUIRED: 13mm & 1/2” socket
wrenches, continuity tester or VOM meter
1. Park the machine on a clean, level surface.
2. Turn off the machine and remove the key.
3. Unplug the positive battery cable at the red
connector (Figure 1).
WARNING: Electrical Shock Hazard.
Disconnect Battery Cables Before Servicing
Machine.
4. Disconnect the operator seat connector
from the main wire harness and lift the seat
from the machine (Figure 1).
Fig. 1
5. Remove the FaST detergent pack
(if equipped) and remove the FaST deter-
gent holder from the front of the battery
compartment shroud (Figure 2).
Fig. 2
6. Remove the two bolts that secure the
battery compartment shroud and lift the
shroud from the machine (Figure 3).
Fig. 3
7. Remove the bolt and flat washer that
connect the control panel mount to the
actuator mount (Figure 4).
Fig. 4