ELECTRICAL
4-119
7100 330695 (8
−
11)
DOES MACHINE
POWER UP ?
POWER WAND & BACKUP ALARM
GO TO POWER
−
UP TESTING
SECTION
No
Yes
IS POWER WAND
ON WHEN
SWITCH (S9) IS
OFF ?
DISCONNECT WAND
SWITCH (S9)
−
WAND
STILL ON ?
Yes
Yes
WAND IS MISWIRED
−
CHECK CONNECTIONS
PER MACHINE
SCHEMATIC
REPLACE
SWITCH (S9)
No
No
CLOSE
SWITCH (S9)
−
DOES WAND
TURN ON ?
Yes
INDICATOR
LIGHT INSIDE OF
SWITCH (S9) ON
WHEN IT IS
CLOSED ?
Yes
SYSTEM
WORKS
CB3 OPEN ?
No
No
Yes
DISCONNECT
POWER WAND
PUMP & RESET CB3
−
FAULT GONE ?
REPLACE
POWER WAND
PUMP
Yes
DISCONNECT
BACKUP ALARM &
ITS RELAY (M7)
−
FAULT GONE ?
No
CIRCUIT 39/WHT IS
SHORTED TO GND
−
LOCATE SHORT &
REPAIR/REPLACE
M7 OR THE HORN IS
BAD OR CIRCUIT 40/
ORA IS SHORTED TO
GND
−
REPAIR/REPLACE AS
NEEDED
Yes
BATT. VOLTAGE
ON 41/PNK @
POWER WAND ?
No
SEARCH FOR
INTERMITTANT
SHORT IN THE
SYSTEM THAT IS
OPENING CB3
13U/BLK IS NOT
CONNECTED TO
MACHINE GND
−
REPAIR/REPLACE
13U/BLK @ BATT.
VOLTAGE ?
Yes
Yes
REPLACE POWER
WAND PUMP IF
CONNECTIONS TO IT
ARE GOOD
No
BATT. VOLTAGE
ON 39A/WHT @
S9 ?
REPLACE S9 IF
CONNECTIONS
TO IT ARE GOOD
No
Yes
CIRCUIT 39/WHT
BETWEEN CB3 &
S9 IS OPEN
−
REPAIR/REPLACE
No
REPLACE CB3 IF
IT’S BAD &
RESET IT
−
FAULT GONE ?
No
Yes
No
Summary of Contents for 7100
Page 1: ...330695 Rev 02 8 11 Service Manual 7100 ...
Page 4: ...GENERAL INFORMATION 1 2 7100 330695 8 11 ...
Page 18: ...GENERAL INFORMATION 1 16 7100 330695 10 00 ...
Page 20: ...CHASSIS 2 2 7100 330695 8 11 ...
Page 72: ...CHASSIS 2 54 7100 330695 8 11 ...
Page 74: ...SCRUBBING 3 2 7100 330695 7 01 ...
Page 97: ...SCRUBBING 3 25 7100 330695 10 00 17 Pull the recovery tank up and out of the machine frame ...
Page 242: ...ELECTRICAL 4 74 7100 330695 8 11 Fig 1 Electrical Schematic S N 7100xxx02700 1 2 3 4 5 6 7 8 ...
Page 244: ...ELECTRICAL 4 76 7100 330695 8 11 Fig 1 Electrical Schematic S N 7100xxx02700 9 10 ...
Page 248: ...ELECTRICAL 4 80 7100 330695 8 11 Fig 3 Wire Harness Group S N 7100xxx02700 ...
Page 249: ...ELECTRICAL 4 81 7100 330695 8 11 Fig 3 Wire Harness Group S N 7100xxx02700 ...
Page 250: ...ELECTRICAL 4 82 7100 330695 8 11 Fig 3 Wire Harness Group S N 7100xxx02700 ...
Page 251: ...ELECTRICAL 4 83 7100 330695 8 11 Fig 3 Wire Harness Group S N 7100xxx02700 ...
Page 252: ...ELECTRICAL 4 84 7100 330695 8 11 Fig 4 Wire Harness Group S N 7100xxx00001 02699 ...
Page 253: ...ELECTRICAL 4 85 7100 330695 8 11 Fig 4 Wire Harness Group S N 7100xxx00001 02699 ...
Page 254: ...ELECTRICAL 4 86 7100 330695 8 11 Fig 4 Wire Harness Group S N 7100xxx00001 02699 ...
Page 255: ...ELECTRICAL 4 87 7100 330695 8 11 Fig 4 Wire Harness Group S N 7100xxx00001 02699 ...
Page 256: ...ELECTRICAL 4 88 7100 330695 8 11 Fig 5 FaST Electrical Schematic S N 7100xxx01709 ...
Page 294: ...ELECTRICAL 4 126 7100 330695 8 11 ...
Page 305: ...ELECTRICAL 4 137 7100 330695 8 11 ...