EN
ENGLISH
8
5100 (02–01)
REMOVING PAD DRIVER OR BRUSH
1.
Raise scrub head to transport position. Step down
firmly on scrub head lift pedal to raise (Figure 16).
FIG. 16
2.
Turn on key switch.
3.
Tilt machine backwards.
4.
While pressing “brush release button”, pull and
release brush trigger quickly. The pad driver/brush
will automatically spin off motor hub. If it doesn’t
release repeat step
(Figure 17).
FIG. 17
NOTE: To prevent scrub head skirt damage, always
keep machine in transport position when pad driver or
brush is not installed.
NOTE: When changing just the pad it’s easiest to
remove pad driver from machine.
FILLING SOLUTION TANK
1.
Transport machine to filling station. Raise
squeegee and scrub head when transporting.
2.
Turn off key switch.
3.
Remove solution tank fill port cover.
4.
Fill solution tank with 28L (7.5 gal) of clean water
using a hose as shown. (60
°
C/140
°
F maximum
temperature). To fill with bucket, use a bucket with
a spout
(Figure 18).
FIG. 18
NOTE: If filling with a bucket be certain that bucket is
clean. This will prevent possible solution line clogs.
5.
Add cleaning chemical. See proper dilution ratio
instructions on chemical container.
6.
Replace solution tank fill port cover.
FOR SAFETY: When using machine follow mixing
and handling instructions on chemical containers.
WARNING: Flammable materials can cause
an explosion or fire. Do not use flammable
materials in tank(s).
7.
If using ES
t
Model, the recovery tank can be
partially filled to extend scrub time.
a.
Remove recovery tank lid and fill tank with 13L
(3.5 gal) of clean water (60
°
C/140
°
F maximum
temperature). Close lid.
b.
Make sure ES
t
switch is turned on when
operating machine (Figure 19).
FIG. 19
c.
The ES
t
light will glow when the ES
t
pump
is recycling.