MAINTENANCE
5680 331176 (9--06)
48
8. Mark the location of the actuator tube on the
actuator shaft before disconnecting the
actuator. Disconnect the actuator from the
scrub head by removing the clevis pin.
9. To install the scrub head, connect the lift
arms to the scrub head with the two clevis
pins.
10. Connect the scrub head to the guide with
the clevis pin.
11. Make sure the actuator tube lines up with
the mark made earlier on the actuator shaft.
If not, turn the actuator tube until it does.
Connect the actuator to the scrub head with
the clevis pin.
12. Connect the wire harness.
13. Connect the solution line to the scrub head
tee fitting.