OPERATION
2-9
235E MM165 (3--91)
CIRCUIT BREAKERS AND FUSES
Circuit breakers are resetable circuit protection
devices designed to stop the flow of current in the
event of a circuit overload. Once tripped, circuit
breakers must be manually reset. If the overload
which caused the circuit breaker to trip is still
present in the circuit, the circuit breaker will
continue to stop current flow until the overload is
corrected.
Fuses are a one-time circuit protection device
designed to stop the flow of current in the event of
a circuit overload. Never substitute higher value
fuses than those specified in this manual.
The circuit breakers are located on the instrument
panel bracket under the seat support. The fuses
are located in the speed controller box.
The following chart shows the various circuit
breakers and fuses, and the electrical
components they protect.
PROTECTIVE
CIRCUIT
DEVICE
RATING
PROTECTED
CB--1
10 A
Battery gauge,
Accessories
CB--2
10 A
Horn
CB--3
10 A
Filter Shaker
CB--4
10 A
Hopper Dump Door
CB--5
2.5 A
Hopper Dump Door,
Thermo Sentry
t
and
Air Flow Solenoids
CB--6
15 A
Lights
FU--1
40 A
Accessory
(Hydraulic Pump) Motor
FU--2
80 A
Propelling Motor
A
B
03367
CIRCUIT BREAKERS
A. Instrument Panel Bracket
B. Circuit Breakers
HOPPER SUPPORT BAR
The hopper support bar is located on the right
side lift arm. The support bar holds the hopper in
a raised position to allow work to be done under
the hopper. Do not rely on the machine hydraulic
system to keep the hopper raised.
WARNING: Falling Hopper. Engage
Hopper Support Bar Before Working
Under Hopper.
Summary of Contents for 235E
Page 1: ...235E MM165 Operator Manual ...
Page 6: ...ABOUT THIS MANUAL 235E MM165 3 91 d ...
Page 14: ...SPECIFICATIONS 235E MM165 3 91 1 2 ...
Page 18: ...OPERATION 235E MM165 3 91 2 2 ...
Page 34: ...MAINTENANCE 235E MM165 3 91 3 2 ...
Page 42: ...MAINTENANCE 235E MM165 3 94 3 10 03380 HYDRAULIC SCHEMATIC ...
Page 70: ...MAINTENANCE 235E MM165 3 94 3 38 ...
Page 72: ...APPENDIX 235E MM165 3 91 4 2 ...