2. When the battery is fully charged there will be four
(4) green lights and one (1) red light showing.
1. Press the button on the battery to illuminate the
LED lights.
POWER LEVEL INDICATOR
4. The charger LED light will be red while charging
and turn green when the battery back is fully
charged. The battery pack may require up to 2.5
hours to fully charge.
After the battery pack is fully charged, the charger
will go into a maintenance mode and keep the battery
fully charged for up to 6 hours then turn off. NOTE:
Battery pack may get warm while charging. This is
normal.
3. Plug the charger DC cable into the Charge Point on
the battery.
The Lithium-Ion battery does not have a memory and
does not have to be fully depleted before it can be
charged again. Charging at any time during the run
cycle will not affect the battery performance or life.
1. The battery Pack is located on the back of the
vacuum. It can be charged while installed on the
vacuum, or the battery can be removed from the
vacuum and charged independently
2. Plug the AC cable into the charger and wall outlet.
CHARGING BATTERY PACK
WARNING:
To reduce the risk of fire, explosion,
electric shock, or injury. When charging, make sure
that the charger has at least 6 inches of clearance
on all sides. Adequate airflow is required to cool the
charger when in use.
WARNING:
To reduce the risk of fire, explosion,
electric shock, or injury. Use only Tennant Charger
1254277 and Tennant battery pack 1237436. Do not
use a battery pack that has been damaged in any
way.
LED
Battery Charger Codes
Red - Charge Cycle in progress
Green - Charge cycle complete
Green Flashing - Maintenance Mode-charge
cycle turns off after 6 hours
Red Flashing - Over voltage protection, unplug
charger and check all connections
Red-Green Flashing - Battery failure, exceeded
minimum threshhold voltage
100 VAC
120 VAC
Summary of Contents for 1254328-V-LWU-13
Page 41: ...V LWU 13B 02 2021 41 JP 120V 120...
Page 42: ...42 V LWU 13B 02 2021 JP 9017544 FLTR HEPA 1 1PKG 6 9009035 PKG of 6 FR 1237436 1254277 HEPA...
Page 43: ...V LWU 13B 02 2021 43 JP 1 2 3 2 7 4 5 6 3 2...
Page 45: ...V LWU 13B 02 2021 45 JP 3 4 0 4 1 2...
Page 46: ...46 V LWU 13B 02 2021 JP 2 1 1 1 2 3 4 3 4 0 4...
Page 47: ...V LWU 13B 02 2021 47 JP 7 6 5 3 2 4 1 4 5 1 2...
Page 48: ...48 V LWU 13B 02 2021 JP 7 8 10 6...
Page 50: ...50 PARTS LIST Tennant V LWU 13B 02 2021 14 12 10 15 9 8 7 6 11 13 1 4 2 3 5 16...
Page 54: ...Tennant V LWU 13B 02 2021 54 NOTES...
Page 55: ...55 Tennant V LWU 13B 02 2021 NOTES...
Page 56: ...9017520 Rev 05 02 2021...