OPERATION
8
Tennant 1180 (03--04)
8. Preheat solution. To maintain or to increase
solution temperature before operating extractor,
rotate PREHEAT/CLEAN knob to PREHEAT
(Figure 4). Activate pump and heater switches.
Solution temperature will rise approximately
0.55
_
C (1
_
F) per minute with a full solution tank.
Maximum achievable solution temperature is
approximately 66
_
C (150
_
F).
FIG. 4
9. Attach vacuum and solution hoses to front of
machine, then to floor or hand tool (Figure 5).
FIG. 5
10. After preheating the solution, turn the pump and
heater switches off momentarily. Then turn the
PREHEAT/CLEAN knob to the CLEAN position.
After turning the knob, turn the pump and heater
switches back on again. IMPORTANT: The pump
switch must always be turned off when turning the
PREHEAT/CLEAN knob to prevent machine
damage (Figure 6). While operating, the CLEAN
mode will increase the preheated solution
temperature an additional 11
_
C (20
_
F) at the
spray tips.
Example: Preheated solution
temperature of 66
_
C (150
_
F) will increase to a
maximum temperature of approximately 77
_
C
(170
_
F).
ATTENTION: DO NOT switch from PREHEAT to
CLEAN mode when pump switch is activated,
pump and gauge damage may occur (not covered
by warranty). Always turn pump switch off before
turning preheat/clean knob.
FIG. 6
NOTE:
In order to get optimum water heat at spray
tips while operating, keep preheat/clean knob in
CLEAN mode. Cleaning in PREHEAT mode will not
harm machine, this will only prevent optimum water
heat at spray tips.
OPERATING FLOOR TOOL
FOR SAFETY: Do not operate machine unless
operator manual is read and understood.
NOTE:
Vacuum carpet before cleaning.
1. Activate vacuum, pump and heater switches.
NOTE:
Be certain that circuit indicator light is on to
verify that two separate circuits are being used.
2. Place floor tool so bottom of glide plate or
stainless steel shoes are parallel to floor. Squeeze
trigger and apply downward pressure on floor tool
head and slowly pull tool backwards using both
hands. Release trigger 150mm (6 in) from end of
stroke (Figure 7).
WARNING: Do Not Pick Up Flammable
Materials Or Reactive Metals.
FIG. 7
Summary of Contents for 1180
Page 2: ......