background image

 

 

 

 

 

3-Phase / Rotation   

Motor Tester 

 

TM-601N / 603 / 604 

 

HB2TM601N000

 

User’s 

Manual 

Summary of Contents for TM-601N

Page 1: ...3 Phase Rotation Motor Tester TM 601N 603 604 HB2TM601N000 User s Manual ...

Page 2: ......

Page 3: ...phases of AC 4 5 2 How to test the motor s direction of rotation 5 6 Easy test 9 7 Electrical specifications 11 8 Accessories included 11 9 Safety precautions and procedures 12 10 The following symbols are used 14 11 Safety and maintenance standards 15 12 Battery Replacement 16 13 Service 19 14 End of life 20 ...

Page 4: ... each other have two sockets to be plugged out before use etc When you use the you will not have these troubles anymore and time is saved So enjoy it 2 Application Test for poles of the 3 phase power source L1 A L2 B and L3 C and identify which phase for which wire Determine the 3 phase motor s direction of rotation clockwise or counterclockwise and the circuit status of the motor wires ...

Page 5: ...ch wire is connected well Check if L1 L2 and L3 are in place the 3 motor wires the motor s direction of rotation and the ER red green OK indicators When the battery is low an indicator will turn ON to remind you to replace it hold the power button and check the panel indicator TM 603 604 Two UL 500mA 700V fuse TM 601N Waterproof resist IP67 TM 601N 4 Panel display 3 red lamps L1 L2 and L3 ER red g...

Page 6: ...d or in power failure mode You may check visually or with a multimeter if the wire is connected well Next check if the red or green lamp is lit If it is the green lamp it suggests L1 L2 and L3 are correct for their phases In this case skip to step 6 If it is the ER red lamp it means L1 L2 and L3 are wired incorrectly You must correct them before proceeding to step 3 Exchange L2 and L3 If the green...

Page 7: ...ng to the next step Exchange L1 and L2 If the green lamp goes ON it means the 3 phases are correct In this case skip to step 6 Note the definition for L1 L2 and L3 each 5 2 How to test the motor s direction of rotation Make sure the motor s power source has been removed Connect the test wire to the motor terminal In each test press the power button then check the indicators on the panel when the m...

Page 8: ...imeter and check if there is a disconnection between any 2 wires If the motor is disconnected change it The green lamp goes ON when the motor turns clockwise and the red lamp turns ON when it turns counterclockwise This suggests the wiring of L1 L2 and L3 is normal In this case skip to step 8 If the red lamp goes ON when the motor turns clockwise and the green lamp goes ON when it turns counterclo...

Page 9: ...Exchange L1 and L3 If the green lamp goes ON when the motor turns clockwise and the red lamp goes ON when it turns counterclockwise skip to step 8 If the red lamp goes ON when the motor turns clockwise and the green lamp goes ON when it turns counterclockwise this indicates the wiring sequence must be corrected Go to step 7 Exchange L1 and L2 If the green lamp goes ON when the motor turns clockwis...

Page 10: ...en lamp goes ON when the motor turns clockwise and the red lamp goes ON when it turns counterclockwise the 3 phases are correct Then the motor s R S T can be connected to the power system s L1 L2 and L3 Now your motor can run correctly ...

Page 11: ...TM 601N 603 604 EN 9 6 Easy test 6 1 1 Motor turning test 6 1 2 Wiring and lamps ...

Page 12: ...TM 601N 603 604 EN 10 Off On not defined Phase indication phase rotation L1 L2 L3 Rotate right Power on Rotate left L1 missing L2 missing L3 missing ...

Page 13: ...with holster 143 68 35 mm Weight including battery about 150g Inter phase voltage 45V AC up to 600 AC Signal Frequency Range 45 to 400 Hz Test Currents In per phase less than 3 5 mA Motor POWER 6W 160W 8 Accessories included User manual 9V battery NEDA 1604 IEC 6F 22 JIS 006P 1carrying case Test leads should be 4 feet long 3 CE120cm 4 feet Test leads should be removable and have alligator clips 3 ...

Page 14: ...dures described in this instruction manual and read carefully all notes preceded by this symbol CAUTION For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this symbol When taking measurements Avoid doing that in humid or wet places Avoid doing that in rooms where explosive gas combustible gas ...

Page 15: ...rts such as test lead ends sockets fixing objects circuits etc Avoid doing that if you notice anomalous conditions such as breakages deformations fractures leakages of battery liquid blind display etc Be particularly careful when measuring voltages exceeding 20V to avoid risks of electrical shocks ...

Page 16: ...ing symbols are used C AUTION refer to the instruction manual an improper use may damage the instrument or its components Danger high voltage risk of electric shock Double insulated meter AC voltage or current DC voltage or current Earth ...

Page 17: ... use expose to pollution level II This is a precision device During use or storage do not go beyond its spec to prevent any possible damage or danger Do not put this device in direct sunlight or where it is hot and or damp Remember to turn OFF the power after use For long storage remove the battery to prevent the battery from leaking to cause damage to the parts inside Clean the device with a dry ...

Page 18: ...ries disconnect the test leads from any energized circuits to avoid electrical shocks Turn OFF the meter and disconnect the test leads from the input terminals Unscrew the battery cover and remove the battery Insert a new battery of the same type 9V NEDA1604 JIS006P IEC6F22 observing the proper polarity re screw the battery cover and reposition the protective holster ...

Page 19: ...ent for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The warranty doesn t apply to Accessories and batteries not covered by warranty Rep...

Page 20: ...nauthorized personnel Instruments for whatever reason modified by the customer himself without explicit authorization of our Technical Dept The contents of this manual may not be reproduced in any form whatsoever without the manufacturer s authorization Our products are patented and our logotypes registered We reserve the right to modify specifications and prices in view of technological improveme...

Page 21: ... for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The manufacturer will not be responsible ...

Page 22: ...TM 601N 603 604 EN 20 14 End of life Caution this symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal ...

Page 23: ......

Page 24: ...ight meter EMF meter UV Light meter RF meter Hot wire Anemometer CO meter Anemometer Lan cable tester CO2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation test Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars com...

Reviews: