TM-601N/603/604
EN-6
turns clockwise, and the red lamp goes
ON when it turns counterclockwise.
(Normal; skip to step 8.) If the motor turns
clockwise and counterclockwise and the
red lamp remains ON (the red and green
lamps do not go ON alternately), this
suggests one wire is disconnected or not
connected well. Please measure the
motor’s 3 wires with a multimeter and
check if there is a disconnection between
any 2 wires. (If the motor is disconnected,
change it.)
The green lamp goes ON when the motor
turns clockwise, and the red lamp turns
ON when it turns counterclockwise. This
suggests the wiring of L1, L2 and L3 is
normal. (In this case, skip to step 8.) If
the red lamp goes ON when the motor
turns clockwise, and the green lamp goes
ON when it turns counterclockwise, this
indicates that the wiring sequence must
be corrected. Go to step 5.
Exchange L2 and L3. The green lamp
goes ON when the motor turns clockwise,