7.  TEST PROCEDURE 

7.1.  POWER BUTTON 

˙

 

Press the “

” button to turn ON the power. The display 

comes alive. 

˙

 

Press the “

” button once again to turn OFF the power 

and put the device go into sleep mode. The display 

changes from light to dark. 

 

7.2.  ZERO“ BUTTON“     

˙

 

Press the “

“button for the zero adjustment if any 

digits are appearing. 

˙

 

If performing the zero adjustment after powering on, 

several digits may not disappear. In this case, perform the 

zero adjustment again. 

 
 
 

Summary of Contents for TM-213

Page 1: ...UV AB Meter TM 213 HB2TM2130002 User s Manual TENMARS ELECTRONICS CO LTD ...

Page 2: ...ATURES 1 3 APPLICATIONS Industrial 1 4 LABORATORY 2 5 NAME AND FUNCTION OF EACH PART 2 6 ELECTRIC SPECIFICATION SPECIFICATIONS 3 7 TEST PROCEDURE 4 8 SAFETY AND MAINTENANCE 6 9 BATTERY REPLACEMENT 6 10 SERVICE 7 11 END OF LIFE 9 ...

Page 3: ...nd 39 99 W cm2 Build Zero button Microprocessor circuit provides high reliability and durability Separate UV LIGHT probe allows user to measure the UV light at an optimum position LCD display easy readout Overload display OL Power off Manual on off by push button or auto shut off after 15 minutes Measurement There 1μw cm2 1 00mW cm2 3 APPLICATIONS INDUSTRIAL Monitoring blue light radiation hazards...

Page 4: ...General laboratory use 5 NAME AND FUNCTION OF EACH PART 5 1 THE LCD DISPLAY SHOWS 1 Main display 2 Reading lock 3 ZERO display 4 Low power reminder display 5 uW cm2 unit display 6 mW cm2 unit display 7 Decimal point display 5 2 BUTTONS 1 The power switch button 2 Backlight button 3 hold lock button 4 zero button 5 UNIT buttons ...

Page 5: ... sunlight ultraviolet Peak sensitivity wavelength 365 nm Sample Time Approx 3 sec Accuracy 3 year Over input Display shows OL Operating Temperature 5 40 below 80 RH Storage temp RH 10 60 below 70 RH Battery life Approx 50 hr Size Main instrument 133 x 48 x 27 mm approx 90g EMC this instrument is EMC compliant and has undergone compatibility tests according to EN61326 1997 A1 1998 A2 2001 ACCESSORI...

Page 6: ...nce again to turn OFF the power and put the device go into sleep mode The display changes from light to dark 7 2 ZERO BUTTON Press the button for the zero adjustment if any digits are appearing If performing the zero adjustment after powering on several digits may not disappear In this case perform the zero adjustment again ...

Page 7: ...ON Press the button to turn ON the power and put the device to operating mode The screen displays 0000uW cm2 Press the button to switch from 0000uW cm2 to 00 00mW cm2 To select a different unit just press this button once again 7 5 DATA HOLD BUTTON Press the button to go into hold mode and appears on the screen to allow you to read the data Press this button once again to deactivate it ...

Page 8: ... remove the battery to prevent the battery from leaking to cause damage to the parts inside Clean the device with a dry soft cloth Wet cloths liquid and water are prohibited 9 BATTERY REPLACEMENT When the symbol is displayed batteries need replacement CAUTION Before replacing batteries disconnect the test leads from any energized circuits to avoid electrical shocks Turn OFF the meter and disconnec...

Page 9: ... for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The warranty doesn t apply to Accessories...

Page 10: ...improvements or developments which might be necessary Service If the equipment is an exception calling repair before you test the battery and test lines and other conditions if necessary replace it If the device still does not operate check whether the operating procedures described in this manual consistent To equipment repair you must return the service at the local address or regional offices t...

Page 11: ...ot forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The manufacturer will not be responsible for any damage to persons or things 11 END OF LIFE Caution this symbol indicates that equipment and its accessories shall be subject to a separate co...

Page 12: ...ght meter EMF meter UV Light meter RF meter Hot wire Anemometer CO meter Anemometer Lan cable tester CO2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation tester Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars co...

Reviews: