Summary of Contents for TM-203

Page 1: ...TENMAIIS Data Logger Light Meter TM 203 HB2ll 12030001 ...

Page 2: ... lnstrument Description See Fig 1 5 7 Operation Procedure 7 8 Relative Spectral SENSITIVITY 8 9 Attention 10 10 Recommended Levels of lllumination 11 11 Battery Replacement 13 12 Setup User end 13 13 User end manipulation menu 14 14 Procedure to instrall USER END Software 16 15 End of life 16 ...

Page 3: ...EN61 326 1 997 41 11 998 A2 2001 T NMAIi5 TM 203 3 PREFACE The flux of light received in a unit area of a ceriain side being shone is popularly known as illumination ln both United Kingdom and America its unit is known as footcandles light but in Europe it is known as meter candlelight One foot candles light is the illumination of light that falls on one side that lies in a distance one foot away ...

Page 4: ...iums building security o Data hold a Zeroadjustment o Large integrated circuit design o Auto power off a Auio range Data logger Maximum hold Minimum hold Average hold Logger stores up to 7000 values T NMARS TM 203 5 SPECIFICATIONS Display 2000 count large LCD display easier to read Sensor Silicon photodiode and filter Measuring Range 20 200 2000 20000 200000 Lux 20 200 2000 20000 Footcandles qccur...

Page 5: ... Lux and footcandles fc DATA HOLD button The reading data shown on LCD can be locked while pressing the button DOWN button Press DOWN cancel Auto Power off and LCT number downward setup 6idsZero Adjustment neC button Press the button to start recording data and prgg s 3 again io stop recording and press f9to leave record display with shown PRESENT Total records 7000 THE MINIMAL INTERVAL IS 1 SECON...

Page 6: ...s not attached CAP is indicated Make sure that it is attached lf performing the zero adjustment after powering on several digits may not disappear ln this case perform the zero adjustment again LCT setting Press both and S at the same time more than 1 second LCT will start to flash lt reminds the user thai LCT can be modified now Then release the pressing from the two buttons press _f button to re...

Page 7: ...ce of light is located at the right top end 0 degree of the light sensor ball plane See fig 2 When the meter is not in use please keep the cap of the light sensor in its place to avoid the photo diode from wearing out When it is not in use for a long time please take the batteries away And avoid keeping it in a place of high temperature and humidity Light Source 0 degree Fig2 EN 1O ...

Page 8: ...ng testing selecting extremely precision visual work 1 500 to 750 Assembling inspecting testing selecting precision visual work 750 io 300 Assembling inspecting testing selectino and visual ordinarv work 300 to 150 Wrapping and packing 75 to 30 lndoor emergency stairwaYs EN 1 1 T NMAR rM 203 Schools lluminance lux lace 1 500 to 300 recision drawing or drafting rrecision exoerimentino librarv 750 t...

Page 9: ... At least 1OMB hard disk space available to install User End program Recommended display resolution is 800X600 or above TM 203 EN 13 EN 14 TENMAFIS TM 203 13 USER END MANIPULATION MENU 13 1 Tool Bar Tool bar section has 6 buttons Connect To Meter Download All Records Erase All Records Update Meier Date Time Save Records to File Print Use button Gonnect to meter to connect meter and PC This step is...

Page 10: ...Group information data section is used to display selected group information including start time end time LUX FC status records number in selected group 13 4 Status Message Staius message is to display current mete status such as recording connected disconnected 13 5 Light Meter Setting Data This section is used to set interval into meter EN 15 EN 16 T NMARs TM 203 13 6 Records Data Data will be ...