Summary of Contents for TM-186

Page 1: ...Medidor tipo Pantalla Termohigrómetro y CO2 TN TM187 ...

Page 2: ...CO2 Monitor TM 186 TM 186D TM 187 TM 187D User s manual HB2TM1860002 ...

Page 3: ... description 8 8 Disable Enable Display 8 9 Mode Set Mode 9 10 Clock and Date setup 9 11 Buzzer ON OFF Setup 10 12 ADJ SET Setup 11 13 Alarm Set Mode 13 14 Alarm Setup 14 15 Battery replacement 17 16 Single data memory 17 17 Viewing logged Data 18 18 Auto Stores Data 18 19 Software installation 19 20 Maintenance 22 21 External DC Power 24 22 End of life 25 ...

Page 4: ...s both the value of CO2 temperature and humidity The selection of C or F Real time data Data Hold function Alarm function 3 General Specifications Display Double rows LED CO2 MAX reading 9999 Temp MAX reading 999 Humidity MAX reading 999 CO2 Sensor Infrared Temp sensor Diode Humidity Sensor Capacitor Sensor Sampling 1 times second Power AC to DC Adapter 9 12V 1A Backup Power 9V battery NEDA ...

Page 5: ...lution 1ppm 0 1 RH 0 1 C 0 1 F Size 260x178x47mm LxWxH Weight 1000g Operating Temperature and Humidity 20 C 70 C 95 RH Non condensing Storage Temperature and Humidity 10 to 60 C 70 RH Non condensing Consumption Current 700mA Standard Accessories User s manual 9V battery AC to DC Adapter Carrying case LCD Wall Mount Accessories Data logging Box Memory Size 30 000 data sets MINI USB 4P MALE to USB A...

Page 6: ...ge CO2 1 9999ppm Humidity 5 95 Temp 20 0 C 70 0 C 4 0 F 158 0 F CO2 Accuracy 70ppm or 5 of reading 0 2000ppm whichever is greater Over 2000ppm 7 Temp Accuracy 1 0 C 1 8 F 0 0 C 40 0 C 32 F 104 F other 2 0 C 3 6 F Humidity Accuracy 3 RH at 25 C 20 80 5 0 RH at 25 C 20 RH 80 RH ...

Page 7: ...e2 When the AC adaptor is off will start the backup power nonly to provide Data Logger use the LED won t be lightened Note3 CO2 sensor have ABC Automatic Baseline Correction algorithm function this function every 7 5days to interval and slowly corrects for any long term drift detected as compared to the expected fresh air value of 400ppm CO2 ...

Page 8: ...187 TM 187D 6 5 Instrument description 1 Time Off Set Set Button 2 Alarm Set Button 3 Temp Unit Button 4 Time Humidity Switch Button 5 Data Hold Button 6 LED Display 7 Single Data Recode Button 8 Read Recode Data Button ...

Page 9: ...TM 187D 7 6 LED description 1 CO2 Reading 2 Temp Reading 3 Time Humidity Reading 4 HI LO Alarm symbol 5 Alarm On symbol 6 Data logger On symbol 7 CO2 unit symbol 8 Temp unit symbol 9 Time unit symbol 10 Humidity unit symbol ...

Page 10: ... Disable Enable Display to toggle Humidity Display on off to toggle Temp Display on off to toggle CO2 Display on off 1 Power Switch 2 Dry Contact MAX input DC24V 1A 3 Calibration Gas Input 4 LO BAT LED 5 Alarm Signal Output 2KHZ 3 3V 6 Power Jack DC9V 12V 1A ...

Page 11: ...d Date Setting Buzzer ON OFF Temp Offset setting Humidity Offset Setting CO2 Offset Setting Auto Recode Time Setting 10 Clock and Date setup Push button into time clock and date setup Push button to select option to adjust Push or button to change the digit ...

Page 12: ...setup then exit the mode If not push button then exit clock and data setup This meter clock shows 12 hour time oringinally if you want to change 24 hours push 11 Buzzer ON OFF Setup Push button into Buzzer ON OFF setup Push or button to change setup ON or OFF ...

Page 13: ...ore the setup then exit the mode If not push button then exit clock and data setup 12 ADJ SET Setup Push button into ADJ setup LED will display ADJ OFF If you just reading alarm setup please push button again to viewing set data push button enable ADJ ...

Page 14: ...n into ADJ data set LED display show ADJ data or button to change the digit Temp adj range 10 10 Humidity adj range 10 RH 10 RH CO2 adj range 200ppm 200ppm If you want to store this setup push the button If not push button then exit alarm setup ...

Page 15: ...m setting Temp HI Alarm setting Temp Gap setting Humidity Lo Alarm setting Humidity HI Alarm setting Humidity Gap setting CO2 Lo Alarm setting CO2 HI Alarm setting CO2 Gap setting Trigger Alarm ON if value L or value H Alarm OFF only manual OFF Gap Alarm ON if value L or value H Alarm OFF value L G or value H G ...

Page 16: ...OFF Push button into Regular Alarm Setting The user has to manually switch on off the alarm even though the current reading value has dropped below your alarm settings which tAg will be shown on the LED dsiplay or Alarm Gap Value settings The meter will automatically switch on off the alarm when the current reading value has dropped below your ...

Page 17: ...m settings which gAP will be shown on the LED display Push button to change Regular Alarm Setting to Alarm Gap Value settings Push button into alarm range setup LED display show LO ALARM ON set LOW Alarm Push or button to change the digit ...

Page 18: ...ON set HI Alarm Push or button to change the digit Push button into alarm Gap value settings Push or button to change the digit If you want to store this setup push the button If not push button then exit alarm setup If test data exceed set range buzzer were bleep at this time socket output sin ...

Page 19: ... Open the battery cover and remove the battery Replace with four 9V NEDA 1604 IEC 6F22 or JIS 006P size battery Install the battery cover 16 Single data memory Push Record button each time to store the display reading and memory location in memory WARNING If the LO Battery LED were turn on please replace the battery immediately ...

Page 20: ...tores time push button to change the temp unit Push or button to change view logged data 18 Auto Stores Data Push button into time clock and date setup Push button again into auto stores time clock setup This time LED display shows auto stores data time you can push to change time unit Max auto stores data time 23hour 59min 59sec Push or button to change the digit Push or button to change the digi...

Page 21: ...then exit auto stores data time setup 19 Software installation Please insert the CD into the PC Please select the USB driver that will be installed such as E PL 2303 Driver Installer exe windows 2000 SP4 windows XP SP2 or go to http www prolific com tw eng download s asp id 31 download new drivel ...

Page 22: ...TM 186 TM 186D TM 187 TM 187D 20 Select the SETUP EXE i e E CO2 Monitor SETUP EXE and installs the desktop icon Tack out the CD from the PC after completed the installation of the desktop icon ...

Page 23: ...TM 186 TM 186D TM 187 TM 187D 21 Use the USB cable to connect the meter and computer according to the drawing Select the desktop icon and click twice on left key of the mouse to run the procedure ...

Page 24: ...nge do not store the unit in an environment with high temperature high humidity and high vibration Take the battery off if the meter has not been used for a long period of time The Diode temperature probe is used to measure temperature and the capacitive humidity sensor is used to measure take humidity ...

Page 25: ...The smoke coal dust grease attached on the protective tube of temperature probe will slow down the heat conduction of the thermocouple and cause measuring error Therefore it should be cleaned periodically The metal coating of thin thermocouple should be replaced properly upon the occurrence of corrosion Cleaning and inspection of humidity sensor The smoke and dust attached on the humidity sensor w...

Page 26: ...essed air instead of water or alcohol The aluminum plate inside the humidity sensor should be replaced upon the occurrence of corrosion 21 External DC Power External AC to DC adapter Voltage 9VDC 8 14VDCMax Socket pin Positive Ground Casing External Diameter 5 5mm internal Diameter 2 1 mm ...

Page 27: ...TM 186 TM 186D TM 187 TM 187D 25 22 End of life Caution this symbol indicates that equipment and its accessories shall be subject to a separ 3ate collection and correct disposal ...