DCV (Auto/Manual)
Range Resolution Accuracy
Input Impedance Overload Protection
4V 1mV
11M
Ω
40V 10mV
400V 100mV
±
(0.8%+2)
600V 1V
±
(1.0%+2)
10M
Ω
DC/AC
660V rms
ACV (Auto/Manual)
Range Resolution Accuracy 50Hz~500 Hz Input Impedance Overload Protection
4V 1mV
11M
Ω
40V 10mV
400V 100mV
±
(1.0%+3)
600V 1V
±
(1.2%+3)
10M
Ω
DC/AC
660V rms
Resistance (Auto/Manual)
Range Resolution Accuracy
Max. Open Voltage Overload Protection
400
Ω
0.1
Ω
±
(0.8%+5)
about -1.5V
DC
4K
Ω
1
Ω
40K
Ω
10
Ω
400K
Ω
100
Ω
4M
Ω
1K
Ω
±
(0.8%+2)
40M
Ω
10K
Ω
±
(3%+2)
About-0.45V
DC
DC/AC
600V rms
(60Second)
Continuity Test
Range Buzzer
Max. Open Voltage
Overload Protection
below 25
Ω
About-1.5V
DC
600V rms
Capacitance (Auto/Manual)
Range Resolution Accuracy
Overload
Protection
4nF 1pF
40nF 10pF
400nF 100PF
4uF 1nF
40uF 10nF
400uF 100nF
±
(3%+10)
4mF 1uF
±
(5%+10)
DC/AC
600V rms
(60Second)
Temperature:optional temp.probe
:
K(CA) type.
Range Resolution Accuracy
℃
1
℃
-50
℃
~ 0
℃
±
(1.8%+2
℃
)
0
℃
~ 500
℃
±
(1.0%+2
℃
)
500
℃
~ 1200
℃
±
(1.8%+2
℃
)
℉
1
℉
-58
℉
~ 32
℉
±
(1.8%+3
℉
)
32
℉
~ 932
℉
±
(1.0%+3
℉
)
932
℉
~ 1999
℉
±
(1.8%+3
℉
)
The tolerance of temp. Probe excluded.
Max.input voltage for thermocouple
:
DC60V,AC24V