To test for continuity, connect the Meter as below:
1.
I
nsert the red test lead into the
terminal and the black test lead into the
COM
terminal.
2.
Set the rotary switch to
, then press blue button to select continuity mode.
3.
Connect the test leads across with the object being measured.
Ɣ
The buzzer does not sound when the resistance value is >30
ȍ
. The circuit is disconnected.
Ɣ
The buzzer sounds continuously when the resistance value is
30
ȍ
. The circuit is in good
condition.
4.
T
he nearest value of the tested circuit is shown on the display in units
ȍ
.
Note
Ɣ
Open-circuit voltage is approx. 3V.
Ɣ
When continuity testing has been completed, disconnect the connection between the testing leads
and the circuit under test.
72-9280: OPERATING MANUAL