3
Front panel controls
1. POWER – Master on/off selector
2. OUTPUT– Power output terminals
3. UVL – Recessed screw adjustment for UVL (upper voltage limit)
4. CURR – Current limit adjustment
5. VOLT – Output voltage adjustment
6. UVL/VOLTAGE – Press to view upper voltage limit
7.
REVIEW – Press to display voltage and current limit settings
8. RANGE – Select desired output voltage and current range
9. OUTPUT ON – Activates supply output
10.
UVL – Upper Voltage Limit Indicator, illuminates when UVL is displayed
11.
C.V. – Constant Voltage Indicator, illuminates when supply is in CV mode
12.
C.C. – Constant Current Indicator, illuminates when supply is in CC mode
13.
ALM – Indicates output voltage is either over the set Upper Voltage Limit or power
supply is in over temperature protection
14.
SLAVE – Illuminates when supply in Slave Mode. No light assumes supply is in
MASTER or stand alone mode.
15. Four Digit Ammeter display
16. Four Digit Voltmeter display
Rear panel connections
17.
MASTER/SLAVE selector – Use select mode in Master/Slave configuration. For
normal operation, this switch should be set to MASTER (default)
18.
OUT/IN terminals – Connections for use in the Master/Slave control parallel
operation mode
19. RS+ and RS– Remote sensing terminals
20. OUT+ and OUT– Alternative output terminals, in some permanent applications the
location of these terminals may be more convenient.
21.
INPUT POWER jack – For connection of supplied AC power cord.