72-14615 Operating Manual

1

Overview

        Digital Bench-Type Multimeter Model 72-14615 is the maximum reading 1999 and 3 1/2 digits, models in manual range, DC / AC current type digital 

multimeter. This is also the extra large characters in LCD display backlight with full function, full measurement and full overload protection as well as 

a good product design outlook. In addition to all the conventional features include DC/AC voltage, DC/AC current, resistance, frequency, capacitance, 

temperature 

, Transistor hFE, diode and continuity buzzer.

        This operating manual covers information on safety and cautions.  Please read the relevant information carefully and observe all the Warnings and 

Notes strictly.

Unpacking Inspection

        Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part.  If you 

find

 any missing or 

damage, please contact your dealer in your country.

    •   Operating Manual 

      

1 piece

    •   Test Lead 

       

1 pair

    •   Alligator Clip         

1 pair

    •   K Type Temperature Probe (For the temperature under 230

testing) 

                1 piece

    •   Multi-Purpose Socket 

      

1 piece

    •   Power Code (AC220V 50Hz DC9V/200mA)     

                1 piece

Safety Information

        This Meter complies with the standards IEC61010-1 in pollution degree 2, overvoltage category (CAT II 1000V) and double insulation. If you can 

not follow up this operating instruction to use the meter and it reduces the chance to have an using protection.

1. Before using the Meter and Test Leads inspect both items.  Do not use the Meter and Test Leads if it is damaged or the case (or part of the case) is 

 

 

removed or no reaction on LCD display. Prohibited to use the meter without housing or housing without screw 

fix

 up in order to avoid possible electric 

 

shock or to avoid possible damage to the meter or to the equipment under test.

2. 

If the damage of test leads, use only the same model number or identical electrical specifications replacement parts.

3. Do not use your finger to touch on any testing cable, connector

, unused terminal input or circuit during the testing stage

4. When the meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken for there is danger of electric shock.

5. Selecting the correct terminal input and turn the rotary switch to select the measuring function.  In case of no any idea on the value input of the 

   

  

current, just simply test from the high value to low one.

6. Do not overload voltage or current on EITHER between terminal and terminal OR between terminal and grounding which indicate on meter limitation.

7. The rotary switch should be placed in the right position and no any changeover of range shall be made during measurement is conducted to prevent 

  

damage of the Meter.

Summary of Contents for 72-14615

Page 1: ...72 14615 Operating Manual 72 14615 ...

Page 2: ...000V and double insulation If you can not follow up this operating instruction to use the meter and it reduces the chance to have an using protection 1 Before using the Meter and Test Leads inspect both items Do not use the Meter and Test Leads if it is damaged or the case or part of the case is removed or no reaction on LCD display Prohibited to use the meter without housing or housing without sc...

Page 3: ...V Fast type melted fuse Φ6 35x31 8mm 6 Frequency input protection PTC 1000V 7 Temperature input protection CE 0 5A 1000V fuse 8 terminal input protection PTC 1000V 9 hFE input protection CE 250mA 265V auto recovery fuse F3 0 5A H 1000V Fast type melted fuse Φ6 35x31 8mm 10 Display LCD full function signal display maximum reading is 1999 72 14615 Updates 2 3 times second 11 Range Manual 12 Polarity...

Page 4: ...t of electrical capacity Accepts the farad the microfarad kHz Unit of Frequency Kilohertz Unit of Temperature Degree Celsius β Factor Unit of Triode enlargement Times 1 Functions Symbol V V Ω kHz A A F hFE Terminal Input V COM V COM V COM V COM V COM mA μA COM 10A COM mA μA COM 10A COM V mA μA Use Multi Purpose Socket V mA μA Use Multi Purpose Socket V mA μA Use Multi Purpose Socket Explanation DC...

Page 5: ...backlight on and off suitable for battery supply backlight turn on about 10 seconds after auto shut down HOLD Press Hold to enter and exit the hold mode in any mode the meter beeps Operational Measurement Guide see Diagram 1 2 3 Diagram 1 Diagram 2 72 14615 Operating Manual ...

Page 6: ...minal input and turns the rotary switch to select the measuring function If fails to do that the buzzer beep and the warning signal flash on Range V Hz Ω mAμA hFE F 10A Alarm Alert On False Terminal Input 10A mAμA 10A mAμA 72 14615 Operating Manual ...

Page 7: ...uring high resistance on 1MΩ or above it is normal to take several seconds to obtain a stable reading In order to obtain stable reading choose shorter test lead to carrying out measurement The test leads and the Meter inside wire will bring around 0 1Ω to 0 2Ω of error to resistance measurement when measuring low resistance To obtain accurate readings in low resistance short circuit the test leads...

Page 8: ...72 14615 72 14615 72 14615 72 14615 72 14615 72 14615 72 14615 ...

Page 9: ...72 14615 Operating Manual 72 14615 72 14615 72 14615 72 14615 72 14615 72 14615 ...

Page 10: ...zzer does not beep When circuit is in good connection with resistance value 10Ω buzzer beeps continuously 72 14615 72 14615 72 14615 1Hz 100Hz 1mV 1Ω 2kHz 200kHz Input Amplitude 2kHz range 50mV a 30Vrms 200kHz range 150mV a 30Vrms 8 Temperature Range 40 to 20 20 to 0 0 to 100 100 to1000 1 72 14615 72 14615 8 5 1 2 4 1 2 3 2 5 2 Resolution Thermocouple It is suitable to use K type thermocouple This...

Page 11: ...marks Ib0 is about 10μA Vce is about 2 5V 72 14615 1β 11 Transistor hFE see Diagram 4 Specifications and other information shown on this instruction manual are subject to change without notice Diagram 4 72 14615 Operating Manual ...

Page 12: ...P N 110401108710X REV 0 DATE 2019 03 12 Tenma Test Equipment 300 S Riverside Plaza 2200 Chicago IL 60606 USA www Tenma com 72 14615 Operating Manual ...

Page 13: ...1 2 3 4 5 6 7 尺寸 尺寸 210X145mm 材质 80g书纸 颜色 单黑印刷 外观要求 装订方式 两枚大钉钉装 表面处理 无 印字完整清晰 版面整洁 无斑墨 残缺破损 毛边 装钉不齐等缺陷 修改 DWH 设 计 MODEL 机型 Part NO 物料编号 110401108710X CHK 审核 APPRO 批准 说明书菲林做货要求 8 REV 0 72 14615 UT801改 邓捷睿19 3 27 ...

Reviews: