8
RUNNING MANUAL
TenarisHydril
CONNECTION SPECIFIC RUNNING GUIDELINES
T
enarisHydril EasyDock™ Connection
Thread Lock Application
1.
Ensure the connections are completely clean and dry
prior to applying thread lock.
2.
Apply thread lock to 50% of the threads behind the
pin sealing area, where the ELS is located.
3.
Do not apply thread lock onto the sealing area,
where the ELS is located.
4.
Apply an even coat of running compound to the box
internal and external torque shoulders and seal surface
area.
5.
Apply the thread lock manufacturers indicated
friction factor.
Torque Application
1.
The use of computer make up analysis equipment is
not necessary to make up EasyDock™ connectors.
2.
EasyDock™ assembles within ¾ of a turn from
stabbing to power tight make up.
3.
A make-up is acceptable if final torque is within
the defined window and there is no visible gap at the
external shoulder.