background image

COMPLETE REFERENCE GUIDE

TEMPUR

®

 ERGO System

© 2010 Tempur-Pedic Management, Inc. 1713 Jaggie Fox Way, Lexington, KY 40511. All Rights Reserved.

TPNA-CRG-TES-0310

Summary of Contents for TEMPUR-Ergo System

Page 1: ...COMPLETE REFERENCE GUIDE TEMPUR ERGO System 2010 Tempur Pedic Management Inc 1713 Jaggie Fox Way Lexington KY 40511 All Rights Reserved TPNA CRG TES 0310 ...

Page 2: ...pplicable document published or approved by Tempur Pedic d to damage to mattresses fabric cables electrical cords or items supplied by Resellers Contact the Reseller or relevant party for warranty information on these items e if there has been any unnecessary service calls including costs for in home service calls solely for the purpose of educating the consumer about the unit for finding an unsat...

Page 3: ...le of Contents SAFETY PRECAUTIONS 4 COMMONLY ASKED QUESTIONS AND ANSWERS 8 SPECIFICATIONS 9 INSTALLATION 10 OPERATION WIRED REMOTE CONTROL FEATURES 18 TROUBLESHOOTING 19 TEMPUR ERGO System Customer Service 1 800 979 1457 ...

Page 4: ...way from heated surfaces Never operate the furnishing with the air openings blocked Keep the air openings free of lint hair and the like Never drop or insert any object into any opening Do not use outdoors Do not operate where aerosol spray products are being used or where oxygen is being administered To disconnect turn all controls to the off position then remove plug from outlet WARNING Risk of ...

Page 5: ...it the reconnection should be made by qualified service personnel Unauthorized modifications could void the electrical portion of your warranty Failure to use a properly grounded outlet for this product or modification of the plug will compromise this important grounding safety feature and may result in electrical shock electrical fire or faulty operation of the product FOR BEST RESULTS YOUR ERGO ...

Page 6: ...his motion as a false sense of movement and or exercise This may or may not affect your pacemaker If you have any concerns please consult your physician USER SERVICEABLE PARTS This product is specifically designed to have no maintenance by you the user Therefore you are encouraged not to open any motors alter the wiring or adjust modify or change the structure of the product as it will void the wa...

Page 7: ...t Dual CA King 300 lbs Queen 425 lbs This Ergo System will structurally support the recommended weight distributed evenly across the head and foot sections Maximum weight per person is 250 pounds This product is not designed to support or lift this amount of weight in the head or foot sections alone NOTE Exceeding the recommended weight restrictions could damage your Ergo System and void your warr...

Page 8: ...ual shipped with the base WHO DO I CALL FOR SERVICE OR SUPPORT IF NEEDED Service and technical support is available by calling our dedicated customer service group at 1 800 979 1457 An owner s manual is included with each base including other information for making claims WHAT IS THE LIFT CAPACITY OF THE ERGO SYSTEM Please see the chart below for Tempur Pedic s recommended and approved total peopl...

Page 9: ... 10 10 1 5 11 9 10 14 2 5 13 4 5 16 2 5 15 3 10 17 9 10 Caster Only Standard Leg without caster Standard Leg with caster 8 Riser Leg without caster 10 Riser Leg without caster 8 Riser Leg with caster 10 Riser Leg with caster C B 14 2 5 4 9 10 53 2 5 38 1 10 19 3 10 62 9 60 1 5 A 12 1 10 37 9 Bed Type A Frame width B Base Width C Base Length Weight Twin Long 30 37 1 2 79 128 lbs Queen 40 58 1 2 79 ...

Page 10: ...n the parts list are included PARTS LIST A Wired Remote Control hardwired to bed 1 B Mattress Retainer Bar 1 C Bed Leg with Caster 4 D Retainer Bar Bolt 4 E Retainer Bar Plate 2 F Allen Wrench 1 G Y Cable For use with King and CA King H 9 Volt Batteries 2 Attached to base for shipping Installation Instructions 10 Customer Service 1 800 979 1457 ...

Page 11: ... locking casters In order to prevent the movement of this product all four casters should be in the locked position You are strongly encouraged to place rubber caster cups or carpet squares not provided under the casters in addition to locking them in place Although the casters lock and will not roll they may slide STEP 3 Remove and extend the power cord and wired remote from the frame WARNING POW...

Page 12: ...em base DO NOT attach the furniture to the Ergo System base DO NOT use slats STEP 6 Plug the power cord into a grounded electrical outlet NOTE An electrical surge protection unit is recommended not included STEP 7 This hand unit is a wired unit and does not require batteries Briefly activate all functions on the wired remote control to verify that all of the features are operational If the bed doe...

Page 13: ...m of the headboard cross member must be positioned so that there is no more than 3 inches between the bottom of the headboard and the top of the mattress Failure to follow this instruction could result in serious injury or death to a person or pet caught between the mattress and the headboard STEP 1 Assemble the Headboard Bracket STEP 1A Use the remote to raise the head of the bed in order to gain...

Page 14: ... open side of the Outer Headboard Bracket C onto the exposed square tube of the Inner Headboard Bracket B This will create a tight fit between B and C Place Bracket Bolts D with a 5 16 inch washer F through the Outer Headboard Bracket C and into the Inner Headboard Bracket B Use 5 16 inch washers F and 5 16 inch nuts G and hand tighten to allow for adjustment Repeat on the other side STEP 1E Ensur...

Page 15: ...les on the Outer Headboard Bracket align with the mounting holes on your headboard Reinstall the bolts on the Outer Headboard Bracket and firmly tighten using the Wrench H and Allen Wrench I STEP 2D Place your headboard bolts through the mounting holes on both the Outer Headboard Bracket and your headboard Firmly tighten STEP 3 Place your Tempur Pedic mattress on top of your Ergo System Base WARNI...

Page 16: ...emote control in a safe place for any future use STEP 6 Remove and extend one of the provided Y cables from the base frame STEP 7 Plug in the A output of the Y Cable into Base A control port STEP 8 Plug in the B output of the Y Cable into Base B control port STEP 9 Plug one of the provided hardwired remote controls into the Control Input side of the Y Cable STEP 10 Route the control cable to your ...

Page 17: ...Installation 17 Customer Service 1 800 979 1457 ...

Page 18: ...position NOTE An unintentional touch to any button that does not illuminate the red LED Signature Light on the wired remote control will cause the keys to light up without performing the associated function Press the appropriate wired remote control button until the red LED Signature Light illuminates to activate the desired function This feature was installed to prevent any undesired movement sho...

Page 19: ... System will activate Unplug the power cord wait 45 seconds and plug it in to reset the electronic components The electrical circuit breaker may be tripped Check the electrical service breaker box to verify The surge protection device or electrical outlet is defective Test the outlet by plugging in another working appliance If bed has been paired confirm that all cables are properly connected espe...

Page 20: ...PPORT OR SERVICE PLEASE CHOOSE FROM THE FOLLOWING NUMBERS QUESTIONS ABOUT YOUR ERGO SYSTEM BASE 1 800 979 1457 QUESTIONS ABOUT YOUR TEMPUR PEDIC MATTRESS OR TO ORDER ERGO SYSTEM ACCESSORIES 1 800 821 6621 OR VISIT WWW TEMPURPEDIC COM 20 ...

Reviews: