Temperature Control Units : With ‘LS’ Series Instrument
Page: 42
TEMPTEK, INC.
525 East Stop 18 Road Greenwood, Indiana 46142
317-887-6352 Fax: 317-881-1277
Service Department Fax: 317-885-8683
www.Temptek.com
assembly back into the
valve body. The stem
should be facing out of
the valve body.
12.
Insert the plunger
with spring first into
the enclosing tube
of the top bonnet
(figure 5.3F). Holding
the plunger in the
enclosure tube, set the
top bonnet onto the
valve body and tighten.
13.
Place the coil onto the
top bonnet and replace
the retaining screw.
14.
Open the water supply
to circulate water to
the system. Check
the solenoid valve
for leakage. Restart
the unit as outlined in
section 3.
5.4
PROBE CALIBRATION
A.
The temperature probe
Coil and solenoid base sub assembly
Body
Gasket
Valve body
Core
assembly
Diaphragm
spring
Diaphragm assembly