Tempsens CALsys 1500 L User Manual Download Page 3

1. General Instruction

1.1 Information on operating instruction

Congratulations   on   your  purchase   of  high-quality  and  efficient  CALsys   1500L   temperature

calibrator.Read this manual carefully to all instructions on safety, operation and maintenance. It
serves as an important source of information and reference for installation and operation of the

device.   The   general   safety   requirements  must  be  strictly   adhered   to  when   operating  the
device.  The  fact  contained   especially  safety   are  observed.  If   you   experience   any  further

questions, please contact our technical support by phone or mail to 

[email protected]

.

1.2 Liability and warranty

This instrument has been manufactured to  exacting standards and is warranted for twelve

months against electrical breakdown or mechanical failure caused through defective material or
workmanship, provided the failure is not the result of misuse. In the event of failure covered

by   this   warranty,   the   instrument   must   be   returned,   carriage   paid,   to   the   supplier   for
examination and will be replaced or repaired at our option.

IN TE R F ER E N CE   WI T H   O R   F A I L U RE   TO   P R OP E R LY   M AI N T AI N   T H IS   IN S TR U M EN T   M A Y
IN V A L I D  TH I S  WA R R AN T Y .  

1.3 Unpacking & Initial Inspection

Our   packing   department   uses   custom   designed   packaging   to   send   out   your   unit,   but   as
accidents can still happen in transit, you are advised, after unpacking the unit, to inspect it for

any sign of damage, and confirm that your delivery is in accordance with the packing note. If
you   find   any   damage   or   find   any   part   missing   during   delivery   notify   us   and   the   carrier

immediately.   If   the   unit   is   damaged   you   should   keep   the   packing   for   possible   insurance
assessment.    

After unpacking you will find following items.

 

 

             

  Calsys 1500 L

     Insulation wool    RS-232 cable          Software CD

 

 

        

 

 

                                                                         R type sensor 

6NOS.Heaters

ceramic Block

Summary of Contents for CALsys 1500 L

Page 1: ...CALsys 1500 L CALsys 1500 L Dry block Temperature Calibrator USER MANUAL TEMPSENS INSTRUMENT I PVT LTD UNIT II...

Page 2: ...2 Circuit diagram 4 Overview 4 4 1 Introduction 4 2 Outline description 5 Operating Instruction 5 5 1 Power 5 2 Setting the temperature 5 3 Operating Instruction 6 Operation of Controller 6 6 1 The T...

Page 3: ...rough defective material or workmanship provided the failure is not the result of misuse In the event of failure covered by this warranty the instrument must be returned carriage paid to the supplier...

Page 4: ...een yellow MUST be connected to a suitable earth Warning Internal mains voltage hazard Do not remove the panels There are no user serviceable parts inside Contact us for repair Do not use the apparatu...

Page 5: ...ncy 50 60 Hz Temperature range 500 to 1500 C Resolution 0 1 C Stability 1 0 C Controlling sensor R type T C Time to reach max Temperature 2 hours Operating Temperature 20 to 45 C Controller Specificat...

Page 6: ...ange of Laboratory calibrators designed and made by us Please contact us in case you required more information about our other products DANGER Power is present even if the front panel circuit breaker...

Page 7: ...ve all packing sheet from inside Insert the heaters in to the groves of SS chamber as per specified same sr no On heater holder and chamber NOTE HEATERS INSERT VERY CAREFULLY Unpack the furnace carefu...

Page 8: ...y screwdriver connect the Phase and Netural wire as per given picture Again fix the front and back plate of calsys 1500L Fix the 6 heater into the chamber and Connect all the aluminum strip in series...

Page 9: ...ully assembled of CALsys 1500L 5 Operating Instruction 1 PID Controller 2 ON OFF switch of controller 3 Power cable RS 232 Power MCB FAN 4 RS 232 cable 5 Safety controller for over heating temperature...

Page 10: ...switch the CALsys 1500 L ON or OFF to raise or lower the temperature The displayed temperature will gradually change until it reaches the setpoint temperature The temperature bath requires 15 to 20 m...

Page 11: ...0L to new location NOTE USE INSULATION WOOL FOR HEAT LOSS AT FRONT SIDE OF CERAMIC BLOCK 6 Operation of Controller FRONT PANEL LAYOUT Operator Buttons 6 1 The Temperature Controller The controller has...

Page 12: ...amp cloth and mild detergent Do not use harsh chemicals on the surface which may damage the paint Avoid knocking or dropping the calibrator If the mains supply cord becomes damaged replace it with a c...

Page 13: ...andevaluate measuring data 1 1 Installation Install the calibration software using the installation guide file on CD ROM After installation of the software Double click the application It willopen th...

Page 14: ...gging up to 120 minutes than clickon start graph button After complete the task clickon save to file button Set Point C in which you can set temperature of furnace as your requirement PVIValue Read th...

Page 15: ...ilicon gel to protect it from humidity Warranty TEMPSENS CALsys 1500L instrument have a warranty of one year from the invoice date This warranty covers manufacturing defects User induced faults are no...

Page 16: ...TEMPSENS INSTRUMENT I PVT LTD...

Reviews: