6.4 Units

Momentary pressing of the Scroll key will show the controller units °C or °F by using SCROLL
key & UP & DOWN key unit can be change.

IMPORTANT NOTICE

The controller's function settings are preset and will not require adjustment. Use only up &
down key.  

7. Maintenance & Trouble shooting

7.1 Maintenance

The calibration instrument has been designed with the utmost care. Ease of operation and

simplicity   of   maintenance   have   been   a   central   theme   in   the   product   development.
Therefore, with proper care the instrument should require very little maintenance. Avoid
operating the instrument in an oily, wet, dirty, or dusty environment.

If the outside of the instrument becomes soiled, it may be wiped clean with a damp cloth 

and mild detergent. Do not use harsh chemicals on the surface which may damage the 
paint.

Avoid knocking or dropping the calibrator.

If the mains supply cord becomes damaged, replace it with a cord with the appropriate 

gauge wire for the current of the instrument. 

Depending on the environment in which it is used, periodic cleaning is recommended. 

Cleaning may be accomplished by the use of the small 

p

aint brush.                                 

7.2 Trouble shooting
1. Unit fails to operate

Check fuse  if it is tripped switch is ON. If not power ON of calsys 1500L  consult us.

 2.

 

Unit unstable

 Controller parameter has been interfered, consult us. 

3. If the temperature of the calibrator is not rising 

(a)

The heating element may be open.  

(b)

The thermocouple may be open. 

(c)

The SSR may be damaged.

(d)

The controller may not be giving output

(e)

The ambient temperature inside the chamber is raised and safety controller switched
OFF the power

 

Summary of Contents for CALsys 1500 L

Page 1: ...CALsys 1500 L CALsys 1500 L Dry block Temperature Calibrator USER MANUAL TEMPSENS INSTRUMENT I PVT LTD UNIT II...

Page 2: ...2 Circuit diagram 4 Overview 4 4 1 Introduction 4 2 Outline description 5 Operating Instruction 5 5 1 Power 5 2 Setting the temperature 5 3 Operating Instruction 6 Operation of Controller 6 6 1 The T...

Page 3: ...rough defective material or workmanship provided the failure is not the result of misuse In the event of failure covered by this warranty the instrument must be returned carriage paid to the supplier...

Page 4: ...een yellow MUST be connected to a suitable earth Warning Internal mains voltage hazard Do not remove the panels There are no user serviceable parts inside Contact us for repair Do not use the apparatu...

Page 5: ...ncy 50 60 Hz Temperature range 500 to 1500 C Resolution 0 1 C Stability 1 0 C Controlling sensor R type T C Time to reach max Temperature 2 hours Operating Temperature 20 to 45 C Controller Specificat...

Page 6: ...ange of Laboratory calibrators designed and made by us Please contact us in case you required more information about our other products DANGER Power is present even if the front panel circuit breaker...

Page 7: ...ve all packing sheet from inside Insert the heaters in to the groves of SS chamber as per specified same sr no On heater holder and chamber NOTE HEATERS INSERT VERY CAREFULLY Unpack the furnace carefu...

Page 8: ...y screwdriver connect the Phase and Netural wire as per given picture Again fix the front and back plate of calsys 1500L Fix the 6 heater into the chamber and Connect all the aluminum strip in series...

Page 9: ...ully assembled of CALsys 1500L 5 Operating Instruction 1 PID Controller 2 ON OFF switch of controller 3 Power cable RS 232 Power MCB FAN 4 RS 232 cable 5 Safety controller for over heating temperature...

Page 10: ...switch the CALsys 1500 L ON or OFF to raise or lower the temperature The displayed temperature will gradually change until it reaches the setpoint temperature The temperature bath requires 15 to 20 m...

Page 11: ...0L to new location NOTE USE INSULATION WOOL FOR HEAT LOSS AT FRONT SIDE OF CERAMIC BLOCK 6 Operation of Controller FRONT PANEL LAYOUT Operator Buttons 6 1 The Temperature Controller The controller has...

Page 12: ...amp cloth and mild detergent Do not use harsh chemicals on the surface which may damage the paint Avoid knocking or dropping the calibrator If the mains supply cord becomes damaged replace it with a c...

Page 13: ...andevaluate measuring data 1 1 Installation Install the calibration software using the installation guide file on CD ROM After installation of the software Double click the application It willopen th...

Page 14: ...gging up to 120 minutes than clickon start graph button After complete the task clickon save to file button Set Point C in which you can set temperature of furnace as your requirement PVIValue Read th...

Page 15: ...ilicon gel to protect it from humidity Warranty TEMPSENS CALsys 1500L instrument have a warranty of one year from the invoice date This warranty covers manufacturing defects User induced faults are no...

Page 16: ...TEMPSENS INSTRUMENT I PVT LTD...

Reviews: