Tempsens CALsys 1200 User Manual Download Page 12

Safety Instructions:

Do's and Don'ts -

*Keep   switch   off   the   red   ON   /   OFF   switch   at   furnace   front   after   switch   off   the   power
supply when furnace not in use.
*Don't remove power cable when furnace is ON.
* Keep cover the block with ceremic wool after insertion sensor for proper insulation.
*Keep down the furnace when not in use before switch off the furnace.
*Don't touch the surface hot part when temperature is high or furnace is in use.
*Don't drop any liquid solution or water upon the furnace.
*Keep place block safely when furnace is OFF.
*Contact our person for any help.

Information

Packing Instruction 

To   transport   or   store   the   instrument,   please   use   the   original   box   or   a     box   padded   with
sufficient shock  absorbing  material.  For  storage  in humid  areas  or  shipment  overseas,  the
device   should   be   placed   in   welded   foil   (   ideally   along   with   silicon   gel)   to   protect   it   from
humidity.

Warranty

TEMPSENS CALsys 1200 instrument have a warranty of one year from the invoice date. This
warranty   covers   manufacturing   defects.   User   induced   faults   are   not   covered   under   this
warranty.

Limit of Liability 
TEMPSENS not liable for any damages that arise from the use of any examples or processes
mentioned in this

 

Specifications are subject to change without notice

 

Copyright:@ 2009, TEMPSENS. All right 

This   document   may   contain   proprietary   information   and   shall   be   respected   as   a

proprietary document   to TEMPSENS with permission for review and usage given only to the rightful

owner of the equipment with which this document is associated. 

TEMPSENS reserves the right to make changes, without further notice, to any product

herein to improve reliability, function, or design . TEMPSENS does not assume any liability arising out of

the application or use of any product described herein, neither does it convey any license under its patent

right nor the right of others.

Copyright:@2009

Summary of Contents for CALsys 1200

Page 1: ...CALsys 1200 CALsys 1200 Dry block Temperature Calibrator USER MANUAL TEMPSENS INSTRUMENT I PVT LTD UNIT II...

Page 2: ...2 Circuit diagram 4 Overview 4 4 1 Introduction 4 2 Outline description 5 Operating Instruction 5 5 1 Power 5 2 Setting the temperature 5 3 Operating Instruction 6 Operation of Controller 6 6 1 The T...

Page 3: ...ctive material or workmanship provided the failure is not the result of misuse In the event of failure covered by this warranty the instrument must be returned carriage paid to the supplier for examin...

Page 4: ...for repair Do not use the apparatus outside its recommended range i e 250 to 1200 C Ensure inflammable materials are kept away from hot parts of the apparatus to prevent fire risk Before connecting to...

Page 5: ...ge 250 to 1200 C Resolution 0 1 C Stability 0 5 C Controlling sensor R type T C Time to reach max Temperature 90 Min Operating Temperature 20 to 45 C Controller Specifications Eurotherm Stabilization...

Page 6: ...The CALsys models are part of wide range of portable calibrators designed and made by us Please contact us in case you required more information about our other products 4 2 Outline Description The c...

Page 7: ...ze the temperature bath within 0 5 C of the set point 5 3 Operating Instruction 1 Insert the inconel block into well of furnace 2 Connect the CALsys 1200 to a suitable power supply Switch ON the Dry b...

Page 8: ...point to the required value The lower display changes to indicate the new set point 6 3 Monitoring the Controller Status A row indicate the controllers status as follows OP1 Heat Output OP2 Cool Outpu...

Page 9: ...recommended Cleaning may be accomplished by the use of a small dry paint brush 7 2 Trouble shooting 1 Unit fails to operate Check fuse if it is tripped switch is ON If not power ON of calsys 1200 bat...

Page 10: ...f software 1 2 Parameter in mainscreen 1 2 1 Communication Communication between the furnace and the software is implemented via a RS 232 cable connected between the furnace and the PC serial port Thi...

Page 11: ...ging up to 120 minutes than clickon start graph button After complete the task clickon save to file button Set Point C in which you can set temperature of furnace as your requirement PVI Value Read th...

Page 12: ...th silicon gel to protect it from humidity Warranty TEMPSENS CALsys 1200 instrument have a warranty of one year from the invoice date This warranty covers manufacturing defects User induced faults are...

Page 13: ...TEMPSENS INSTRUMENT I PVT LTD...

Reviews: