Tempsens CALsys 1200 User Manual Download Page 1

CALsys 1200

CALsys 1200

 

Dry block Temperature Calibrator 

 USER MANUAL

TEMPSENS INSTRUMENT (I) PVT. LTD UNIT II

Summary of Contents for CALsys 1200

Page 1: ...CALsys 1200 CALsys 1200 Dry block Temperature Calibrator USER MANUAL TEMPSENS INSTRUMENT I PVT LTD UNIT II...

Page 2: ...2 Circuit diagram 4 Overview 4 4 1 Introduction 4 2 Outline description 5 Operating Instruction 5 5 1 Power 5 2 Setting the temperature 5 3 Operating Instruction 6 Operation of Controller 6 6 1 The T...

Page 3: ...ctive material or workmanship provided the failure is not the result of misuse In the event of failure covered by this warranty the instrument must be returned carriage paid to the supplier for examin...

Page 4: ...for repair Do not use the apparatus outside its recommended range i e 250 to 1200 C Ensure inflammable materials are kept away from hot parts of the apparatus to prevent fire risk Before connecting to...

Page 5: ...ge 250 to 1200 C Resolution 0 1 C Stability 0 5 C Controlling sensor R type T C Time to reach max Temperature 90 Min Operating Temperature 20 to 45 C Controller Specifications Eurotherm Stabilization...

Page 6: ...The CALsys models are part of wide range of portable calibrators designed and made by us Please contact us in case you required more information about our other products 4 2 Outline Description The c...

Page 7: ...ze the temperature bath within 0 5 C of the set point 5 3 Operating Instruction 1 Insert the inconel block into well of furnace 2 Connect the CALsys 1200 to a suitable power supply Switch ON the Dry b...

Page 8: ...point to the required value The lower display changes to indicate the new set point 6 3 Monitoring the Controller Status A row indicate the controllers status as follows OP1 Heat Output OP2 Cool Outpu...

Page 9: ...recommended Cleaning may be accomplished by the use of a small dry paint brush 7 2 Trouble shooting 1 Unit fails to operate Check fuse if it is tripped switch is ON If not power ON of calsys 1200 bat...

Page 10: ...f software 1 2 Parameter in mainscreen 1 2 1 Communication Communication between the furnace and the software is implemented via a RS 232 cable connected between the furnace and the PC serial port Thi...

Page 11: ...ging up to 120 minutes than clickon start graph button After complete the task clickon save to file button Set Point C in which you can set temperature of furnace as your requirement PVI Value Read th...

Page 12: ...th silicon gel to protect it from humidity Warranty TEMPSENS CALsys 1200 instrument have a warranty of one year from the invoice date This warranty covers manufacturing defects User induced faults are...

Page 13: ...TEMPSENS INSTRUMENT I PVT LTD...