OFL100
Tempo Communications Inc.
1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
14
VFL
7KHYLVXDOIDXOWORFDWRULVXVHGWRLQMHFWUHGODVHUOLJKW
LQWRWKHƬEHUXQGHUWHVWWRDOORZWKHWHFKQLFLDQWR
YLVXDOO\ORFDWHEUHDNVRU0DFUREHQGVLQƬEHURSWLF
cables. The VFL can also locate contaminated and
damaged connectors.
Open:
Turns the visual fault locator on in continuous
wave mode.
1Hz:
9LVXDOIDXOWORFDWRUƮDVKHVDW]
2Hz:
9LVXDOIDXOWORFDWRUƮDVKHVDW]
Close:
7XUQRƪYLVXDOIDXOWORFDWRU
WARNING
Avoid looking directly at the laser output port;
permanent eye damage may occur
OPM
The OPM can be used to measure absolute and
relative power. The OPM can identify and measure
WRQHZDYHOH]+]N+]DQGN+]
emitted from a compatible laser.
Wavelength:
Set the desired wavelength.
Reference:
Set the current power as the reference.
The Relative power will be set to 0dB where loss
measurements can be made.
Calibration:
Enter the calibration mode.
7KUHVKROG
Set the threshold value of power
measurement. If it exceeds the threshold value, it will
be displayed in red; if it is lower than the threshold
value, it will be displayed in green.
(YHQW0DS
6WDUWRIƬEHU
Raleigh loss event such as a fusion
Connector
Splitter
End of link
5LVLQJHYHQWFDXVHGE\WKH
inconsistency of refractive index of two
VHFWLRQVRIƬEHU