Program Thermostat Owners Manual 

Model: TESPR22 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FEATURES 

Structure of thermostat and explanation for the keypads 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
We are pleased you have selected one of our broad line of wall thermostat. Our products 
are manufactured to high quality standards and are designed for years of service.   

Read This Before Installing Thermostat 
OPERATION 

YOUR THERMOSTAT REPLACES 

Description 

TESPR22 

Heat Pump (No Aux. or Emergency Heat) 

Yes 

Heat Pump (with Aux. or Emergency Heat) 

Yes 

Standard Heat & Cooling Systems 

Yes 

Two Stage Heat & Two Stage Cool 

Yes 

Standard Heat Only Systems 

Yes 

Millivolt Heat Only Systems

– Floor or Wall Furnaces 

Yes 

Standard Central Air Conditioning 

Yes 

Gas or Oil Heat 

Yes 

Electric Furnace 

Yes 

Hydronic (Hot Water) Zone Heat-2 Wires 

Yes 

Hydronic (Hot Water) Zone Heat

–3 Wires 

No 

This Thermostat will NOT control 110/220Volt systems. 

IMPORTANT 

2

,

  Read  the  entire  installation  section  of  this  Owner

’s  Manual  thoroughly  before  you 

begin to install or operate your Thermostat.

   

This  thermostat  can  be  used  for  conventional  or  heat  pump  system, 
Please  configure  the thermostat  according  to  Configuration  Menu 
before operation.

 

REMOVE THE MYLAR LABEL FORM THE LCD DISPLAY WINDOW. 

INSTALLATION 

3

,   

All installation is normally performed at your thermostat. 

ARMCHAIR PROGRAMMING 

4

You  can  program  your  thermostat  before  installation  by  inserting  the  batteries  and 

following the instructions starting configuration menu.This can be done while you relax in 
your favorite chair and is a very good way to familiarize yourself with all the functions of 
your thermostat. 

The following time and temperature settings are pre-programmed into the thermostat: 

 

 

Temperature in 

˚F (˚C) 

Program Number 

Time 

Heat 

Cool 

6:00 am 

68

˚F(20˚C) 

78

˚F(26˚C) 

8:00 am 

60

˚F(16˚C) 

85

˚F(29˚C) 

4:00 pm 

68

˚F(20˚C) 

78

˚F(26˚C) 

10:00 pm 

60

˚F(16˚C) 

82

˚F(28˚C) 

COMPRESSOR PROTECTION

 

5

The  thermostat  provides  a  4  minutes  delay  after  shutting  of  the  heating  or  cooling 

system before it can be restarted. This feature will prevent damage to your compressor 
caused by rapid cycling. Note that this delay also applies to the heating system control. It 
does not provide a delay when there are power outages.you can select the function on 
or off at the configuration.   

TEMPERATURE RANGE 

6,  This  thermostat  can  be  programmed  between 

45˚F  and  95˚F  (7˚C  and  35˚C). 

However, it will display room temperatures from 30˚F to 99˚F (0˚C and 37˚C). “HI” will be 
displayed if the temperature is higher than 99˚F (37˚C), and “LO” will be displayed if the 
temperature  is  lower  than  30˚F  (0˚C).This  thermostat  will  automatically  cutoff  in  Heat 
mode if the temperature rises above 95˚F (35˚C), and automatically cutoff in Cool mode 
if the temperature drops below 45˚F (7˚C). 
NOTE: if the thermostat measure a temperature over 99

˚F(37

), 

”HI” will be displayed 

on  the  LCD.  if  the  temperature  is  below  32

˚F(0

).  and 

”LO”  will  be  displayed  on  the 

LCD,. 

POWER FAILURE 

7

  Whenever the main power is interrupted or fails, the battery power retains and 

current time. This thermostat has permanent memory, although you will have to reset 
your clock when there are power outages.

 

POWER SUPPLY

 

8

The thermostat shall be powered by 24 VAC and with batteries as backup. 

BATTERY WARNING

 

9

Fresh alkaline batteries should provide about one year of service. However, when the 

batteries  become  drained, 

“BATT”  will  alternate  on  the  display  with  the  current  time. 

When this message occurs, install 2 new AA batteries, You have approximately 1 minute 
to  change  the  batteries  and  keep  thermostat

’s  clock  and  program  settings.  Once  the 

batteries have become too low to ensure proper operation, your system will be turned off, 
and the display will be cleared except for 

“BATT” flashing on the LCD display. 

CAUTION: 

Once only the 

“BATT” only display occurs, the thermostat is shut down, and 

your system will no longer operate. In this condition, there is no temperature 
control  of  your  dwelling.   

NOTE:  The  backlight  will  not  function  when  the 

thermostat is in low battery condition. 
NOTE:  If  you  plan  to  be  away  from  the  premises  over  30  days,  we 

recommend that you replace the old batteries with new alkaline batteries prior to 
leaving. 
INSTALLATION 

What You Need 
This thermostat includes two  #8 slotted screws and two wall anchors for mounting. To 
install your thermostat, you should have the following tools and materials. 
■ Slotted Screwdriver(s)          ■ Small Philips screwdriver            ■ Hammer 
■ Electric drill and 3/16” bit      ■ Two1.5V (AA) size alkaline batteries (included) 

CAUTION: 
To  prevent  electrical  shock  and/or  equipment  dam-  damage,  age,  disconnect 
electric  power  to  system  at  main  fuse  or  circuit  breaker  box  until  installation  is 
complete.

 

Before removing wires from old thermostat's switching subbase, label each wire with the 
terminal designation it was removed from. 
1.  Shut  off  electricity  at  the  main  fuse  box  until  installation  is  complete.  Ensure  that 
electrical power is disconnected. 
2.  Remove  Old  Thermostat:  A  standard  heat/cool  thermostat  consists  of  three  basic 
parts: 
a. The cover, which may be either a snap-on or hinge type. 
b. The base, which is removed by loosening all captive screws. 
c.  The  switching  subbase,  which  is  removed  by  unscrewing  the  mounting  screws  that 
hold it on the wall or adaptor plate.   
3. Remove the front cover of the old thermostat. With wires still attached, remove wall 
plate  from  the  wall.  If  the  old  thermostat  has  a  wall  mounting  plate,  remove  the 
thermostat and the wall mounting plate as an assembly. 
4. Identify each wire attached to the old thermostat. 
5.  Disconnect  the  wires  from  the  old  thermostat  one  at  a  time.  DO  NOT  LET  WIRES 
FALL BACK INTO THE WALL. 
6. Install new thermostat using the following procedures. 

WARNING 

Do  not  use  on  circuits  exceeding  specified  voltage.  Higher  voltage  will  damage 
control and could cause shock or fire hazard. Do not short out terminals on gas 
valve or primary control to test. Short or incorrect wiring will damage thermostat 
and could cause personal injury and/or property damage.   
Selector Switches

 

Electric/Gas Switch (Fan Option) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 1. Electric/Gas Switch (Fan Option) 

This thermostat is configured from the factory to operate a heat/ cool, fossil fuel (gas, oil, 
etc.), forced air system. It is configured correctly for any system that DOES NOT require 
the thermostat to energize the fan on a call for heat. If you system is an electric heat or 
heat-pump  system  that  requires  the  thermostat  to  turn  on  the  fan  on  a  call  for  heat, 
locate the ELEC/GAS switch on the back of the thermostat (see fig. 1) and switch it to 
the ELEC position. This will allow the thermostat to energize the fan immediately on a 
call for heat. If you are unsure if the heating/ cooling system requires the thermostat to 
control the fan, contact a qualified heating and air conditioning service person. When the 
thermostat is configured for Heat Pump, the thermostat will always power the circulator 
fan on a call for heat in the HEAT mode. The ELEC/GAS switch must be set to match the 
type of Auxiliary heat your system uses for proper operation in the EMERgency mode. 
All  wiring  diagrams  are  for  typical  systems  only.  Refer  to 

equipment  manufacturers’ 

instructions for specific system wiring information. 

Attach Thermostat Base to Wall

 

1. Remove the packing material from the thermostat. Gently pull the cover straight off the 
base. Forcing or prying on the thermostat will cause damage to the unit. 
2. Connect wires beneath terminal screws on base using appropriate wiring schematic 
(see figs. 2 through 4). 
3. Place base over hole in wall and mark mounting hole locations on wall using base as 
a template. 
4. Move base out of the way. Drill mounting holes. 
5. Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. Place a 
level against bottom of base, adjust until level, and then tighten screws. (Leveling is for 
appearance  only  and  will  not  affect  thermostat  operation.)  If  you  are  using  existing 
mounting  holes,  or  if  holes  drilled  are  too  large  and  do  not  allow  you  to  tighten  base 
snugly, use plastic screw anchors to secure subbase. 
6.  Push  excess  wire  into  wall  and  plug  hole  with  a  fireresistant  material  (such  as 
fiberglass insulation) to prevent drafts from affecting thermostat operation. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 2. Thermostat base

 

 
 
 
 
 
 

 
 

Figure 3 Typical wiring diagram for single transformer heat pump systems 

 
 
 

 
 
 
 
 

Figure 4. Typical wiring diagram for two transformer heat pump systems with NO safety circuits 

 
 
 
 
 
 
 
 

Figure 5. Typical wiring diagram for two transformer  heat pump systems  with safety circuits in 

BOTH systems 

Heat Pump Terminal Outputs 

Refer  to  equipment  manufacturers'  instructions  for  specific  system  wiring  information. 
You  can  configure  the  thermostat  for  use  with  the  following  heat  pump  system  types: 
HEAT PUMP TYPE 1 1. Single stage compressor system; gas or electric backup. This 
thermostat  is  designed  to  operate  a  single-transformer  system.  If  you  have  a 
two-transformer system, cut and tape off  one transformer. If transformer safety circuits 
are  in  only  one  of  the  systems,  remove  the  transformer  of  the  system  with  NO  safety 
circuits. If required, replace remaining transformer with a 75VA Class II transformer. After 
disconnecting one transformer, the two commons must be jumpered together. 
Use the terminal output information below to help you wire the thermostat properly for 
your  heat  pump  system.  After  wiring,  see  CONFIGURATION  section  for  proper 
thermostat configuration. 

THERMOSTAT TERMINALS (HEAT PUMP)

 

SYSTEM

 

Heat Pump 1

 

Heat Pump 2

 

L

 

Malfunction

 

C*

 

24 Volt(Common)

 

R

 

24 Volt Emergency (hot)

 

E/W1

 

Emergency Mode 1st stage

 

W2

 

HP 1 and Emergency 2nd stage

 

Y1

 

Heat and Cool mode 1st stage (compressor)

 

Y2

 

No output 

2nd stage compressor 

G

 

 

Blower/Fan Energized on call for Heat and Cool 

Set GAS/ELEC switch for Emergency mode

 

O

 

Energized in Cool Mode

 

Energized in Heat Emergency mode

 

 
 
 
 
 
 
 
 
 

Figure 5. Typical wiring diagram for single transformer multi-stage systems

 

CHECK THERMOSTAT OPERATION

 

Note: 
To  prevent  static  discharge  problems,  touch  side  of  thermostat  to  release  static 
build-up before touching any keys. 
If  at  any  time  during  testing  your  system  does  not  operate  properly,  contact  a 
qualified serviceperson.

 

Fan Operation 

If your system does not have a G terminal connection, skip to Heating System System. 
1. Turn on power to system. 
2. Move FAN switch to ON position. The blower should begin to operate. 

3. Move FAN switch to AUTO position. The blower should stop immediately 

Heating System

 

1. Move system switch to heat mode. If the auxiliary heating system has a standing pilot, 
be sure to light it. 
2.  Press  to  adjust  thermostat  setting  to  1

  above  room    temperature.  The  heating 

system  should  begin  to 

operate.  The  display  should  show  “STG1”.  However,  if  the 

setpoint  temperature  display  is  flashing,  the  compressor  lockout  feature  is  operating 
(see Configuration menu, item 5). 
3. Adjust temperature setting to 3° above room temperature.If your system configuration 
is set at MS2, HP2 or HP1, the auxiliary heat system should begin to operate and the 
display should show “STG1+2” 2”. 
4. Press to adjust the thermostat below room temperature. The heating system should 
stop operating. 

Emergency System

 

EMER  bypasses  the  Heat  Pump  to  use  the  heat  source  wired  to  terminal  E  on  the 
thermostat.  EMER  is  typically  used  when  compressor  operation  is  not  desired,  or  you 
prefer back-up heat only. 
1. Press SYSTEM switch to select Heat mode. then press EMER key.

. “EMER” will show 

on the display.

 

2. Press to adjust thermostat setting above room temperature. The Aux. heating system 
will  begin  to 

operate.  The  display  will  show  “STG1”  “EMER”  to  indicate  that  the  Aux. 

system is operating. 
3. Adjust temperature setting to 2°C above room temperature.The auxiliary heat system 
should begin to operate and the 

display should show “STG1+2”. 

4.  Press  to  adjust  the  thermostat  below  room  temperature.  The  Aux.  heating  system 
should stop operating.

 

Cooling System

 

1. Move SYSTEM switch to select the Cool mode. 
2. Press to adjust thermostat setting below room temperature. The blower should come 
on immediately on high speed, followed by cold air circulation. The display should show 
“STG1”.   
3. Adjust temperature setting to 2°C below room temperature. The second stage cooling 
should begin to operate and 

the display should show “STG1+2”   

4. Press to adjust the temperature setting above room temperature. The cooling system 
should stop operating. 

 

CONFIGURATION MENU 

INSTALLER/CONFIGURATION MENU 

Step 

 

Press 

Button 

Displayed 

(Factory Default) 

Press up or down 

key to select 

Comments 

 

MS 2 

SS1, HP2, HP1 

Selects Single stage, Multi-stage, 

or Heat Pump (Single stage or 

2-stage) System Configuration 

(RECO)off 

on 

Auto Recovery select 

(SPAN)2 

1,3 

Span(one stage) 

(BLIT)on 

off 

BackLight 

(SP2)2 

1,3 

Span(Two Stage) 

(TEMP)F 

Selects temperature 

display °F or °C 

HOUR(12) 

24 

Selects time format display 

12hours or 24hours 

COMP(OFF) 

ON 

Selects Compressor 

Lockout OFF or ON 

COOL(2) 

This model must select 2 

10 

FACT(0) 

1,2 

Select 2,all the setting will 

go back to factory default 

The configuration menu allows you to set certain thermostat operating characteristics to 
your system or personal requirements. Set SYSTEM switch to OFF, then simultaneously 
press up and down keys to enter configuration menu. The display will show the first item 
in  the  configuration  menu.The  configuration  menu  table  summarizes  the  configuration 
options. An explanation of each option follows.Press F key to change to the next menu 
item. To exit the menu and return to the program operation, press Hold/Run Key. If no 
keys are pressed within fifteen Seconds, the thermostat will revert to normal operation. 
1)Single Stage, Multi-stage or Heat Pump System Configuration   
This  control  can  be  configured  for  Heat  Pump  or  two  stage  heat/one  stage  cool 
multi-

stage operation.The display indicates “MS 2” (default for multi-stage mode) in the 

display. The Multi-stage configuration can be 

toggled to “SS1”, or “HP1” by pressing the 

up or down key. In Multi-stage configuration, EMER mode is useless. 
2) Select Energy Management Recovery OFF or ON

 

Your thermostat is set from the factory to gradually recover the room temperature from 
an energy saving program to your comfort program. Therefore, the thermostat may turn 
your system on several minutes prior to your programmed.   
3)Fast or Slow Crycle Selection(one stage) 
4)Select Backlight function OFF or on 
5) Fast or Slow Crycle Selection(two stage) 
6)Select  °F  or°C  Readout.  when  you  change  this  parameter.the  programming  come 
back to fault. you have to set the programming again. 
Changes the display readout to Centigrade or Fahrenheit as required 
7) Selects time format display 12hours or 24hours 
8)Select Compressor Lockout COMP OFF or ON 
Selecting COMP ON will cause the thermostat to wait  4 minutes before turning on  the 
compressor  if  the  heating  and  cooling  system  loses  power.  It  will  also  wait  5  minutes 
minimum  between  cooling  and  heating  cycles.  This  is  intended  to  help  protect  the 
compressor  from  short  cycling.  Some  newer  compressors  already  have  a  time  delay 
built in and do not require this feature. Your compressor manufacturer can tell you if 
the lockout feature is already present in their system. When the thermostat compressor 
time delay occurs it will flash the setpoint for about four minutes. 
9) This model must select 2 
10) This model must select 2 to back factory Default 
 

Setting Time And Day 

Remove the mylar label covering the LCD display window before operating thermostat. 

■ Initial display after power-up. The temperature will 
      update after a few seconds.   

EXAMPLE: Set the Thermostat to the current time of 9:43 a.m. on 

  Saturday Refer to Figure at right 

■ During time and day setting mode , the temperature 

      and program display will go blank.   

■ Press and hold to rapid advance to the current hour. 
    Tap to advance one hour at a time. Note the AM /PM 

indicator, as the display will cycle through 24 hours.   

■ Press and hold to rapid advance to the current 

minute

.

 

  Tap to advance one minute at a time. 

■ Tap to advance one day at a time. 

■ When finished press to return to normal mode. 

    After 15 seconds, the thermostat will return to normal       
automatically. 

Auto Programming       

Studies  conducted  by  the  Department  of  Energy  estimate  that 
setting  your  thermos

tat  back  10˚F  (6

)  for  two  8-hour  periods 

during  winter  can  reduce  your  fuel  bill  by  as  much  as  much  as 
33%.  By  setting  your  thermostat  up  5

˚F  (3

)  for  tow  8-hour 

periods during summer you can reduce your fuel bill up to 25%. 
Your thermostat is capable of holding up to 4 separate programs   
for each day ofthe week. You can program all weekdays, Monday 
to Friday, to the same 4 programs as show in the table, or each 
weekday  can  have  a  different  set  of  4  programs.  Similarly 
weekend  programs,  Saturday  and  Sunday,  can  be  the  same  4 
programs or each weekend day can have a different set of 4 programs. 
Your thermostat is pre-programmed to meet the ENERGY STAR  guidelines for  energy 
efficiency. Note that it is easier to modify these programs than to 
programs than to program the thermostat manually. 

■  Press  once.  During  Auto  Programming,  the 
display will change as shown.   
■ The thermostat will be programmed for all 7 days 
of the week as shown below. 

 

Temperature in 

˚F/

 

Program Number 

Time 

Heat 

Standard 

6:00am 

68 

˚F    (20

78 

˚F    (26

8:00am 

60 

˚F    (16

85 

˚F    (29

4:00pm 

68 

˚F    (20

78 

˚F    (26

10:00pm 

60 

˚F    (16

85 

˚F    (29

■    Refer to Manual Programming entering or changing the programs. 

PROGRAMMING   

Before programming or changing programs, use this Personal 
Program Schedule to determine which times and temperature 
Settings  will  best  satisfy  both  your  comfort  and  energy  saving  requirements.    Use  a 
pencil so you can revise yours records each time you change your temperature settings.                                         

AUTO
PROG

Overrides energy-
saving program

For entering 
hour of day.

For entering 
minute of day.

Enters Program Mode
for reviewing and changing
weekday, weekend,or daily
programs.

Measures and displays
heating and cooling system
operating time for Today,
Yesterday,This Week,Last
Week,or Total. By monitoring

Automatically programs the
thermostat to its built-in

Selects the day or days to
review or change in Program
Mode.

Provides permanent temperature setting
by overriding stored programs. It also

Returns display to current

time and temperature.

For entering day of week.

HOME

HOUR

MIN

ENER

AUTO

PROG

DAY

PROG

PROG

DAY

TODAY

temperatures while
you are at home
for the day.

your energy usage, you can
program the thermostat to
optimize energy savings.

ENERGY STAR    compliant
program setting.

R

returns the thermostat to current program
control from manual override or Home
Today mode.

EMER

HOLD
/ RUN

EMER Mode.

DAY

HOUR

MIN

HOLD
/ RUN

TEMP

LCD Display: Shows Time,Day,Temperature,Program Number,and 
other feature information as required.

Temperature Keys:
Keys for raising or lowering
temperature setting.

Reviews filter usage
in hours and minutes.
Also resets filter
counter to zero.

Front Door: 

         Cover keys Open with one finger from left or right.

Soft touch programming
buttons (see below)

Fan Switch: Fan
switch for Automatic
or Continuous fan
operation.

System Switch:
Selector switch for
Cool,Off,Heat or auto.

heat 

off

cool

auto

FAN

SYSTEM

ON

AUTO

K2

Elec-Gas

Switch

GAS

ELE

C

Mounting
Hole

Mounting
Hole

Mon  

AM

4

TEMP

                                          Sat 

AM

                                          Sat 

AM

TEMP

 Sat  Sun

 

AM

2

HEAT

TEMP

Mon  Tue  Wed  Thu  Fri  

Mon  Tue  Wed  Thu  Fri  Sat  Sun

 

AM

PM

1 2
3 4

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

2nd Stage
Compressor

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 
Heat
Relay

Hot
120 VAC
Neutral

 

    

  

TRANSFORMER

(Class    Current 

Limited)

24 VAC

Remote
Sensor

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

2nd Stage
Compressor

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 

Heat
Relay

Hot
120 VAC

Neutral

    TRANSFORMER
(Class 

 Current Limited)

24 VAC

      

Limit or Safety
 Switches

Remote
Sensor

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

2nd Stage
Compressor

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 
Heat
Relay

Limit or
 Safety
 Switches

Limit or
 Safety
 Switches

HOT

120 VAC

   Heat Pump Transformer
(Class     Current Limited)

24 VAC

Limit or Safety
 Switches

COMMON

HOT

120VAC

Auxiliary
 Heating 
Transformer
(Class 
Current Limited)

24VAC

Limit or
 Safety
 Switches

      NEUTRAL

      NEUTRAL

COMMON

     

The accessory relay scheme 
is required when safety
circuits ezist in both systems

Remote
Sensor

Reversing 

  Valve 

Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

Fan
Relay

Heat
Relay
Stage 1

Compressor
Contactor
Stage 1

    

Heat
Relay
Stage 2

Compressor
Contactor
Stage 2

Remote
Sensor