6
MAINTENANCE PROCEDURES
Although Tempest Variable Speed
Power Blowers
TM
are designed
to eliminate most maintenance issues, it is imperative that the
blowers be inspected before startup on each use. Please review the
following list before using this product.
MAINTENANCE SCHEDULE
EVERY USE
• INSPECT BLOWER FOR DAMAGE AND FIX IF
ANY
• TIGHTEN/REPLACE ANY LOOSE OR MISSING
PARTS
EVERY MONTH OR 10 HOURS
• INSPECT & CLEAN SHROUD & GRILLES
IMPORTANT: Always operate the blower in an area free
of debris which may be pulled into the unit’s blades. If you
suspect the fan’s blade may have contacted a hard object,
thorough inspection of the blade assembly should be
conducted immediately to ensure safety. You may contact
Tempest Technology Corp. in order to find out how to
properly inspect the blade assembly.
POWER BLOWER
TM
TROUBLESHOOTING
Various factors can contribute to or be the sole cause of problems
for electric power blowers. This section will identify some of these
problems and provide solutions to correct them.
BLOWER WILL NOT START WHEN RHEOSTAT TURNED
• Confirm that adequate power is being supplied to blower. If
power supply is adequate,
DISCONNECT BLOWER FROM
POWER SOURCE
and check for loose or faulty wiring on
blower electrical system and repair if needed.
• Connect blower to power source and attempt restarting. If
blower does not run,
DISCONNECT BLOWER FROM
POWER SOURCE,
remove the drive cover and check the
internal wiring connections.
• Check the internal fuse located on the circuit board of the
drive.
• If the blower will not start and all electrical connections
have been checked, the
VSM
drive may need to be replaced.
Contact Tempest at 800.346.2143 or response@tempest.
us.com for assistance.
BLOWER MOVEMENT OR “WALKING”
• Adjust the rubber footpads on the back of the blower by
turning them either in or out.
• Adjust the side that is walking. This will help to evenly
distribute the weight of the blower to all four points of the
frame.
• Most blowers will walk if not running at full speed, make sure
the blower is running at full speed.
• Ensure the blower is sitting flat and not on small rocks or
other objects.
• If blower is still walking, contact Tempest at 800.346.2143 or