Tempest VSM Series Owner'S Manual Download Page 4

 4

POWER BLOWER

TM

 DATA

Positive Pressure Ventilation Fan, Cone Air Flow (CAF)

Direct-Drive Variable Speed 110-120V, 60Hz Electric Motor, GFCI Compatible

AirFlex Fiberglass Reinforced Polyamide Blades

      

Keyed Shaft and Set or Cap Screws

Turbo 2000 Tapered Aluminum w/ Durable Powder-Coat Finish

Rugged, Lightweight, Square-Steel Tubing with Powder-Coat Finish

Foot-Operated Tilt Mechanism 

16” Models: Four Position Tilt, +10°, +5°, 0°, -5°

18”, 21” Models: Five Position Tilt, +15°, +10°, +5°, 0°, -5°

18”, 21” BASIC Models: Three Position Tilt, +15°, +10°, 0° (Hand-Operated)

Continuous Circular-Wound, External-Weld Steel Wire with 8 Tie Points for Additional Safety

Meets UL & European CE Safety Standards

Steel-Reinforced Rubber and Welded Steel Spring Feet

16” Models: 6” Non-Pneumatic w/ Steel Hubs

18“, 21” Models: 8” Non-Pneumatic w/ Steel Hubs

TYPE: 

DRIVE:  

BLADE: 

      

BUSHING:

SHROUD: 

FRAME: 

TILT MECHANISM: 

GRILLE: 

VIBRATION DAMPENERS: 

WHEELS:

(NON BASIC)

VSM SPECIFICATIONS:

VSM BASIC SPECIFICATIONS:

Model No.

Part No.

Size HP CFM

Dimensions (WxDxH)

Weight

VS-16-M-0.5

910-1500

16” 0.5 10,650

21.00” x 19.75” x 21.75”

68 lbs.

VS-18-M-0.8

910-1520

18” 0.8 8,465

23.00” x 21.00” x 24.25”

82 lbs.

VS-21-M-0.8

910-1540

21” 0.8 11,475

26.00” x 21.00” x 26.25”

86 lbs.

Model No.

Part No.

Size HP CFM

Dimensions (WxDxH)

Weight

VS-18-M-0.8 BASIC

910-1521

18” 0.8 8,465

22.00” x 18.50” x 24.00”

58 lbs.

VS-21-M-0.8 BASIC

910-1541

21” 0.8 11,475

25.00” x 18.50” x 25.50”

61 lbs.

Summary of Contents for VSM Series

Page 1: ...OWNER S MANUAL Power BlowersTM Cone Air Flow CAF Electric Driven VSM Series 0216_01A...

Page 2: ...l Free 800 346 2143 t 559 277 7577 f 559 277 7579 response tempest us com www tempest us com TABLE OF CONTENTS ABOUT TEMPEST 2 SAFETY GUIDE 3 GENERAL INFORMATION 3 POWER BLOWERTM DATA 4 POWER BLOWERTM...

Page 3: ...ur Tempest Power BlowerTM 9 Only a qualified technician should perform repairs or maintenance on electric components 10 Never operate your Tempest Power BlowerTM with electric components exposed 11 Ne...

Page 4: ...e Points for Additional Safety Meets UL European CE Safety Standards Steel Reinforced Rubber and Welded Steel Spring Feet 16 Models 6 Non Pneumatic w Steel Hubs 18 21 Models 8 Non Pneumatic w Steel Hu...

Page 5: ...r BlowerTM a highly effective and efficient ventilation tool As with any new technique Positive Pressure Ventilation requires training and education in order to be implemented properly and safely Temp...

Page 6: ...rrect them BLOWER WILL NOT START WHEN RHEOSTAT TURNED Confirm that adequate power is being supplied to blower If power supply is adequate DISCONNECT BLOWER FROM POWER SOURCE and check for loose or fau...

Page 7: ...MBLY LEFT DARK GREY 610 1001K 610 1020K 610 1020K 15 LEG ASSEMBLY RIGHT DARK GREY 610 1002K 610 1021K 610 1021K 16 FRAME DARK GREY 610 1302K 610 1322K 610 1342K 17 FRONT GRILLE DARK GREY 610 1400K 610...

Page 8: ...rt No 13 WHEEL 715 OF 7X1 50 OFFSET 240 001 14 HANDLE RECEIEVER ASSY 18 21 BASIC 610 1659 15 PULL UP HANDLE FOR BASIC 600 286K 16 BASIC WHEEL MOUNT LEFT 610 1657 17 BASIC WHEEL MOUNT RIGHT 610 1658 de...

Page 9: ...9 NOTES...

Page 10: ...10 NOTES...

Page 11: ...11 NOTES...

Page 12: ...ditions and Tempest will replace any defective power blower part except the engine or motor and drive if returned during the applicable warranty period for the time frame indicated below Fire ghting I...

Reviews: