13 

 

7.1

 

Setting up 

Fill the fluid tank with an approved 

LEADER

 fluid as shownon 

page 16.

 

7.2

 

Final checks   

Before applying power to the machine, verify the following: 

 

The machine is safely located or installed and meets the location requirements stated on 

page 11. 

 

The operator is familiar with, and able to comply with, the requirements for safe operation 
listed on 

page 4

 

The fluid is one of the Approved 

LEADER

 fluids listed under “Approved fluid types”                 

on 

page 16

 

The machine is electrically grounded (earthed). 

 

The AC power distribution circuits and lines are adequately rated for the current load. 

7.3

 

Turning on the power  

 

 

Set the mains switch on the rear of the unit, to the 

‘ON’ (I)

 position. 

The display will show 

HEAT

When the display shows 

READY

                               the unit is ready to produce smoke. 

 

To obtain maximum output, wait another few minutes after the 

READY

 indication                               

is shown, as the machine continues to heat to full operating temperature and fog output is 
reduced while the unit is heating up. 

 

 

 

 

 

 

 

 

 

HEAT 

READY 00% 

READY 00% 

Summary of Contents for Leader SMOKE 3

Page 1: ...1...

Page 2: ...2...

Page 3: ...0 113 LEADER Smoke 3 600 m per minute 220 v 50 60 Hz R20 00 114 LEADER Smoke 5 1320 m per minute 220 v 50 60 Hz R20 00 115 LEADER Smoke 3 600 m per minute 115 v 50 60 Hz R20 00 116 LEADER Smoke 5 1320...

Page 4: ...Setting up 13 7 2 Final checks 13 7 3 Turning on the power 13 8 CONTROL SETTINGS 14 8 1 Overview 14 8 2 Setting smoke output level 14 8 3 Setting continuous operation 15 8 4 Setting the Timer 15 8 5 R...

Page 5: ...ity 2 SAFETY INFORMATION LEADER Smoke 3 and LEADER SMOKE 5 Read the safety precautions in this manual before installing operating or servicing this product The following symbols are used to identify i...

Page 6: ...pilled on to electronic parts take the machine out of service and contact LEADER for advice Do not remove the covers or attempt to repair a faulty machine Refer any service not described in this manua...

Page 7: ...ified technician Fog output can cause condensation Do not point the output at smooth floors Floors and surfaces may become slippery Check these frequently and wipe dry as necessary to avoid any danger...

Page 8: ...start technology Fluid sensing system Easy external fluid hook up Optional ducting kits Use only an approved LEADER fog fluid as shown on page 16 Use of other fluid will void warranty Physical LEADER...

Page 9: ...tion Fluid reservoir 2 5 L drop in reservoir with quick connect fitting 5 L drop in reservoir with quick connect fitting External fluid control Fluid sensing Remote control Integrated digital remote w...

Page 10: ...0 6 3 EU Immunity EN 61000 6 1 Australia NZ pending RCM 4 PRODUCT DETAILS LEADER Smoke 3 LEADER Smoke 5 Warning High temperature vapour and surfaces Fluid pipe connection Fluid container Integrated di...

Page 11: ...240 V EU 1800 W 15 A 110 V Now set the mains switch on the rear of the unit to the ON I position The display will show HEAT After about 6 8 minutes the display should show READY and the current progr...

Page 12: ...ER Make sure the power plug is correctly rated For UE LEADER Smoke 3 and LEADER Smoke 5 models use a plug rated at 10 A minimum When installing the plug follow the plug manufacturer s instructions and...

Page 13: ...LEADER fluids listed under Approved fluid types on page 16 The machine is electrically grounded earthed The AC power distribution circuits and lines are adequately rated for the current load 7 3 Turni...

Page 14: ...ote control by removing the two hand wheel bolts either side of the display 8 2 Setting smoke output level Use the output UP DOWN buttons to select the desired output performance Once the value is sel...

Page 15: ...o toggle between runtime and offtime To enable the run timer function set a non zero value to the runtime using the timer UP DOWN buttons When runtime is zero the runtime is shown as OFF indicating th...

Page 16: ...nput is provided for applications requiring an additional means of triggering the machine other than the remote control The rear mounted XLR socket provides 12V DC at 50mA to power an interface device...

Page 17: ...rainer fluid Heavy This fluid is used when maximum persistence is required or a very heavy density of fog is required to simulate a complete white out DANGER The LEADER Smoke range machines can run sa...

Page 18: ...r compressed air Clean fog fluid residues from the fog output of the machine using a damp cloth Clean the outer casing with a damp cloth only 10 2 Fuse replacement The main fuse for the machine is loc...

Page 19: ...age 17 No power at AC cable inlet Check power cable and circuit breaker Loss of control from remote Communication issue between remote and machine Check cable connection between remote and machine Mes...

Page 20: ...20 Notes...

Page 21: ...21...

Page 22: ...tment ZI des Hautes Vall es Chemin No 34 CS 20014 76930 Octeville Sur Mer France OUT OF WARRANTY EQUIPMENT A complete analysis will be carried on your faulty equipment after which a detailed quote wil...

Page 23: ...23...

Page 24: ...24 Code Notice LEADER SMOKE 3et 5 00 ZN4 33 EN 0...

Reviews: