02/19 Pamphlet No. 3986
© temperzone limited 2019
OPA 1370RKTMG-P – Wiring Diagram Part 3, of 3
Drawn:
Apprvd:
Title:
Drawing
No:
Rev:
Date:
©temperzone Ltd 2017
DO
NOT
SCALE
- ASK
Client
Wiring
SHEET
OF
33
C
291-000-581
Wiring
Schematic
OPA
1370RKTMG-PZ
UC6
A.K.B
27-12-2017
1)
Crankcase
Heater
Note
24
Hour
power
required
(on
L1)
for
control
curcuit
and
crankcase
heaters
Important Notes:
Cooling
-
kW
Electrical
Input
Supply
required
3Ph
380-415V
~
50Hz
A/Ph
Indoor
Fan
Motor
(3Ph)
kW
Outdoor
Fan
Motor
(1Ph)
Full
Load
amps
A
Weight-Nett
Heating
- Reverse
Cycle
kW
Compressor
1 (3Ph)
run
amps
rating
conditions
MFD
kW
kW
Cooling
-
Heating
- Reverse
Cycle
Kg
Indoor
Fan
Motor
(3Ph)
Full
Load
amps
Capacities
- Nett
to
AS/NZS
3823
kW/kW
E.E.R.
(Cooling)
Compressors
type
: Scroll
Compressor
Oil
Type
Control
Circuit
Breaker
Indoor
Fan
Motor
Circuit
Breaker
Indoor
Fan
Motor
Overload
settings
Compressor
Overload
settings
Single
Phase
Socket
Circuit
Breaker
24
Volt
Circuit
Breaker
A A A
Outdoor
Fan
Motor
Capacitor
Compressor
Circuit
Breakers
A A
A A
IFM
IFCB IFOL
CCB 24VCB
CMCB CM
OL
CM
SPSCB
Electrical
A.E.E.R
(Cooling)
Outdoor
Fan
Motor
1
&
2
Circuit
Breaker
A
OFCB
kW/kW
3.55
30.1
37.7
132
134
3.54
Refrigerant
Charge
- per
system
Kg
20
x
4
4.5
x4
4
x
4
1.9
x
4
15
P.O.E
4A
10A
x
2
22A
x
4
2A
32A
x
4
16A
N/A
1370RKTM
OPA
10.7
2297
3)
TFC
Dip
Switch
Settings
SW1
SW2
SW3
SW4
Off
Off
Off
Off
2)
Important
Note
Compressors
fitted
are
directional.
If
rotation
incorrect,
compressor/s
will
not
pump,
be
noisy,
and
draw
minimal
current.
To
correct
rotation,
reverse
two
phases.
BB1
BB2
N
HEAT1 24V
COMP2
24V
COMP1
24V
24V CO
M
M
TB5
24V
Client
Wiring
Sensors
(S)
/ Transducers
(T)
Name
Type
Colour
ST1
Suction
Temp
S
BLUE
ST2
Suction
Temp
S
BLUE
DT1
Discharge
Temp
S
GREY
DT2
Discharge
Temp
S
GREY
SP1
Suction
Pressure
T
SP2
Suction
Pressure
T
HP1
High
Pressure
T
HP2
High
Pressure
T
TS1
De-ice
Temp
S
BLUE
TS2
De-ice
Temp
S
BLUE
OAT
Ambient
Temp
S
YELLOW
A/Ph
Compressor
2 (3Ph)
run
amps
rating
conditions
15
A/Ph
Compressor
3 (3Ph)
run
amps
rating
conditions
15
A/Ph
Compressor
4 (3Ph)
run
amps
rating
conditions
15
Running
Amps
(total)
Max
Running
Amps
A/Ph
A/Ph
Outdoor
Fan
Motor
3
&
4
Circuit
Breaker
A
OFCB
16A
10A
HEAT2 24V
COMP3
24V
COMP4
24V
IFM 24V
65/73/73 96/105/105
24VCB
24
VOLT
CIRCUIT
BREAKER
BB
BUS
BAR
C12ER
COMPRESSOR
1&2
ENABLE
RELAY
C34ER
COMPRESSOR
3&4
ENABLE
RELAY
CAP
CAPACITOR
CBL
COMPRESSOR
CABLE
CCB
CONTROL
CIRCUIT
BREAKER
CCH
CRANKCASE
HEATER
CMC
COMPRESSOR
CONTACTOR
CMCB
COMPRESSOR
CIRCUIT
BREAKER
CMM
COMPRESSOR
MOTOR
CMOL
COMPRESSOR
OVERLOAD
CR
COMPRESSOR
RELAY
DMF
DAMPER
MOTOR
FRESH
AIR
DMR
DAMPER
MOTOR
RETURN
AIR
EEV
ELECTRONIC
EXPANSION
VALVE
ETH
EARTH
STUD
HR
HEAT
RELAY
IBB
INSULATED
BUS
BAR
IFC
INDOOR
FAN
CONTACTOR
IFCB
INDOOR
FAN
CIRCUIT
BREAKER
IFM
INDOOR
FAN
MOTOR
IFOL
INDOOR
FAN
OVERLOAD
IFR
INDOOR
FAN
RELAY
MIS
MAIN
ISOLATOR
SWITCH
M
V
MODULATING
VALVE
OFCB
OUTDOOR
FAN
CIRCUIT
BREAKER
OFM
OUTDOOR
FAN
MOTOR
PRC
PHASE
ROTATION
CONTROLLER
PLR
PHASE
LOSS
RELAY
RV
REVERSING
VALVE
SPSCB
SINGLE
PHASE
SOCKET
CIRCUIT
BREAKER
SPS
SINGLE
PHASE
SOCKET
TFC
TRIAC
FAN
CONTROLLER
TJ
TERMINAL
JOINER
TR
TRANSFORMER
UC6
UNIT
CONTROLLER
6
(201-000-485)
L1
L2
L3
MIS
Main
Isolator
Switch
A
200A
Fit
links
as
shown
ONLY
if
using
TZT-100
connected
to
UC6
"T/ST
terminals
OR
a
BMS
which
communicates
with
the
UC6
via
mod
bus
Client
External
Protection
and
Isolator
switch
APPROVED
DATE
ECN
DESCRIPTION
REV C
01-02-19
A.W.G.
Spec
data
updated.
N4188
C