CMD 

Function 

Example 

Units: 

Sets monitor to Celsius or Fahrenheit 

U:F 

P1: 

Sets 1st phone number 

P1:8605551212 

P2: 

Sets 2nd phone number 

P2:8605552424 

P3: 

Sets 3rd phone number 

P3:8605553636 

P4: 

Sets 4th phone number 

P4:8605554848 

UID: 

Names the monitor 

UID:Mountain Cabin 

AU: 

Upper temp limit of internal sensor 

AU:85 

AL: 

Lower temp limit of internal sensor 

AL:35 

AT: 

Time delay of internal temperature sensor 

AT:2 

AID: 

Internal sensor name 

AID:Room Sensor 

HU: 

Upper limit of internal humidity sensor 

HU:70 

HL: 

Lower limit of internal humidity sensor 

HL:0 

HT: 

Time delay of internal humidity sensor 

HT:15 

HID: 

Humidity sensor name 

HID:Humidity 

BU: 

Upper limit of  external sensor 1 

BU:30 

BL: 

Lower limit of  external sensor 1 

BL:-10 

BT: 

Time delay of external sensor 1 

BT:5 

BID: 

External sensor 1 name 

BID:Freezer 

CU: 

Upper limit of  external sensor 2 

CU:20 

CL: 

Lower limit of  external sensor 2 

CL:-15 

CT: 

Time delay of external sensor 2 

CT:10 

CID: 

External sensor 2 name 

CID:Refrigerator 

PT: 

Power outage time delay 

PT:1 

WT: 

Water sensor time delay 

WT:1 

RT: 

Text message reminder/repeat time 

RT:120 

ST: 

Status update time 

ST:13 

D1: 

Door sensor 1 time delay 

D1:2 

1ID 

Door 1 name 

1ID:Front Door 

D2: 

Door sensor 2 time delay 

D2:2 

2ID 

Door 2 name 

2ID:Garage Door 

PW: 

Sets the password 

PW:5964 

CPW: 

Clears the set password 

CPW:5964 

Summary of Contents for CM712

Page 1: ...Model CM712 Manual and Installation Instructions...

Page 2: ...ion 3 Installation 4 Programming with a Cell Phone 5 Command Function Table 6 Commands Explained 7 8 10 Settings Table 9 Programming with email 11 Wiring Diagram 12 Querying the CM712 13 Text Examples...

Page 3: ...ing for up to 10 hours without power CM712 will also send a warning text when the battery voltage gets below 5 8VDC This setting is not user adjustable The CM712 is programmed and notifies you of alar...

Page 4: ...e power off by sliding the power switch to the OFF position Remove the power jack Remove the four screws holding the cover on Insert the SIM card into the SIM slot Replace the cover insert and tight t...

Page 5: ...t case sensitive except for password programming All commands cannot be sent at once in a single text message It is recom mended that it be broken into several different messages If possible pro gramm...

Page 6: ...T Time delay of internal humidity sensor HT 15 HID Humidity sensor name HID Humidity BU Upper limit of external sensor 1 BU 30 BL Lower limit of external sensor 1 BL 10 BT Time delay of external senso...

Page 7: ...sent AT AT 2 This example sets the time delay of the internal temperature sensor to 2 minutes This means that once the temperature went out of range the monitor would wait 2 minutes before sending tex...

Page 8: ...monitor will continue to send text alerts every 2 hours as long as the condition remains in alarm Zero is the de fault and is disabled when set to zero ST ST 13 This example would send a status messa...

Page 9: ...AT 0 0 900 AID Internal Temp 2 16 characters HU 100 10 95 HL 0 5 85 HT 0 0 900 HID Humidity 2 16 characters BU 200 BL 200 BT 0 0 900 BID External Temp 1 2 16 characters CU 200 CL 200 CT 0 0 900 CID Ex...

Page 10: ...way to clear it is to set the monitor back to factory defaults That can only be done by turning the monitor off pressing and holding the reset button while turning it back on It can be done remotely...

Page 11: ...er in a single email It won t work Break it into sev eral separate emails See table on pg 5 The subject line must contain the ten digit cellular telephone number you would like the monitor to respond...

Page 12: ...12 External Temp 1 UL 200F LL 200F T 0 min External Temp 2 UL 200F LL 200F T 0 min Room Temp UL 85F LL 33F T 2 min Room Humidity UL 90 LL 10 T 10 min Sent from Mountain Cabin...

Page 13: ...to the phone it was sent from Text will include the programmed tem perature limits humidity limits and their respective time delays Delays delays Sending a text message with the word delays to the mo...

Page 14: ...m Text 6 Example Bu 55 bl 25 bt 5 Bid AC Sensor Text 7 Example Cu 55 cl 25 ct 5 cid Outside Temp Text 8 Example Pt 2 Wt 0 Rt 20 St 20 Text 9 Example D1 1 1ID Front Door Text 10 Example D2 0 2ID Server...

Page 15: ...e Product is 1 damaged by extraneous causes such as fire water lightning etc or not maintained as reasonable and necessary 2 modified 3 improperly installed 4 repaired by someone other than the Warran...

Page 16: ...16 Microtechnologies Inc www temperatureguard com sales temperatureguard com support temperatureguard com Rev 712 r6...

Reviews: