ZPOINT Rev 1.0  |   http://www.temperaturealert.com/  |  © 2013 Temperature@lert

 

 

 

 

 

 

 

 

 

 ZPoint Node 

 TM-ZP200 

 TM-ZP200-TH 

 User Guide 

 

 

 

 

Summary of Contents for TM-ZP200

Page 1: ...1 ZPOINT Rev 1 0 http www temperaturealert com 2013 Temperature lert ZPoint Node TM ZP200 TM ZP200 TH User Guide...

Page 2: ...choosing Temperature lert to protect your highly valuable belongings from unexpected changes in temperature or other potentially harmful environmental factors We hope that you will find our products...

Page 3: ...tting Up Your First Alert 10 TEMPERATURE LERT ZPOINT NODES IN DETAIL 11 ZPoint Node Indicator Lights 11 Status Light 11 Warning Light 12 Failure Light 12 Light Indicator Reference Table 12 ZPoint Jack...

Page 4: ...4 ZPOINT Rev 1 0 http www temperaturealert com 2013 Temperature lert Failure Light is Flashing 18 Warning Light is Flashing 18 SPECIFICATIONS 19 OBTAINING SERVICE AND SUPPORT 20 REGULATORY NOTICES 21...

Page 5: ...ucts and services our customers want at a price they believe delivers good value and the peace of mind they expect We have a long history of designing devices to measure environmental changes Our line...

Page 6: ...eway at the same time Benefits ZPoint provides customers with capabilities and benefits to make it the most user friendly cost effective wireless temperature and humidity sensor on the market today Th...

Page 7: ...plications such as refrigerated Food and Medical Supply distribution ZPoint Models At least one Cellular Edition ZPoint Gateway is needed for operation You can connect wired sensors directly to the ga...

Page 8: ...readings goes too high or too low the system will call email or text message you Zpoint Nodes can transmit temperature readings every 5 minutes for up to 5 years on the included AA batteries If the m...

Page 9: ...NOT see the red failure light blink Verifying Wireless Signal Reception Your Temperature lert ZPoint Nodes transmit sensor readings via 2 4GHz radio waves to the ZPoint Cellular Gateway In order for...

Page 10: ...lick on the Device List tab 2 In the Device List table click on the view link for your device 3 Scroll to the bottom of the page 4 Next to Sensor Alerts click the Edit link 5 Click the Add Alert link...

Page 11: ...Edition ZPoint Gateway please visit temperaturealert com support and download the Cellular Edition ZPoint Gateway User Guide Each Node powers on and looks for a Gateway The Nodes will automatically fi...

Page 12: ...g normally even if the warning light is flashing Failure Light When operating properly the failure light will be off However the failure light will flash twice every 30 seconds to indicate there was a...

Page 13: ...ensor The TM ZP200 TH includes built in temperature and humidity sensors Sensor Jack 1 2 The sensor jacks accept Temperature lert environmental sensors The unit will monitor up to two external sensors...

Page 14: ...l strength indicator mode use a ballpoint pen or paperclip and push the On Off button for 3 seconds All lights will come on When the status light begins flashing you can release the On Off button The...

Page 15: ...ou wish to turn it on please contact support to ensure you have a monitoring plan that supports it Store and Forward data transmitted to Sensor Cloud is not evaluated for alarms Therefore if you utili...

Page 16: ...re lert Cellular Edition ZPoint Gateway in order to operate The range will vary depending on your location but is generally several hundred feet through walls If a signal is unavailable in the desired...

Page 17: ...Batteries The status of the batteries can be seen from the device view page on the Sensor Cloud website In addition you can setup a low battery alarm to notify you when the batteries are low on power...

Page 18: ...e further assistance Warning Light is Flashing A warning light does NOT indicate a fault or failure The device is still transmitting successfully as long as the red failure light is not flashing The w...

Page 19: ...None Built in Temperature Sensor Range 40 C to 60 C 200 C to 200 C with optional probe Built in Temperature Sensor Accuracy 0 5 C Accuracy from 10 C to 70 C Built in Humidity Sensor Range TM ZP200 TH...

Page 20: ...imple and easy to use Of course we do realize that questions and other issues can pop up at any time So we d love to hear from you If you require assistance at any time please visit http www temperatu...

Page 21: ...es Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause u...

Page 22: ...r The device is approved to work with a 1 2 wavelength dipole SMA RP antenna with maximum gain of 2 2dbi Under Industry Canada regulations this radio transmitter may only operate using an antenna of a...