13
Temco VF36RN/RNH/RP
78586
Installation of Optional Wireless Remote
Two remote control kits are offered. The standard ON/
OFF model is a WRD-1 and the thermostatic model is a
WRST-K.
The remote receiver should be placed in the lower
compartment of the fireplace behind the control cover
panel.
There will be a battery terminal and two wire leads.
The remote receiver does not need to be secured to the
fireplace but can be placed on the floor under hearth
pan assembly.
The enclosed jumper wires can be attached to the
receiver wires by joining the female connectors from
the receiver.
All connections should be made as shown in the
remote kit instructions. The jumper wire should be
routed behind the cover plate to the valve. The wires
from your receiver can be connected to the two outer
terminals on the valve, making sure it is the two outer
terminals and not the center one. (Figs. 12 and 13) You
may now refer to the lighting instructions for use. The
log set should not be modified to accept any other type
of remote control as no guarantee may be made
regarding proper function. Refer to manufacturer’s
instructions for battery replacement.
T147
Fig. 12 Connect wires from receiver to terminals on valve.
B
B
A
A. Existing valve wiring (Do not tamper with)
B. Remote receiver wires (red or white on either side)
Fig. 13 Attach receiver wires to outer two terminals on valve.
Installation of Millivolt Wall Switch
To install your millivolt wall switch, an approved wall box
should be installed in a location suitable to you. The
thermostat wire should be routed from the wall box to
the log set and should be routed underneath the log set
and pulled up to the valve’s wiring terminal as shown in
Figure 15.
The two wires, letter “A”, should not be removed or
changed. Remove switch wires, Letter B. The two
female ends of your wire can be connected to the two
outer connections just below the screw terminals as
shown in Figures 12 and 15.
Now the wall switch can be wired as shown in Figure
14. The wires can be connected to either poles as they
carry only millivolt current. No ground is used at the
wall switch. See the lighting instructions on Page 14.
Wall switch must be for millivolt operation.
Do not connect 120 Volts to wall switch.
Wire Size
Maximum Length
14 ga.
50’
16 ga.
32’
18 ga.
20’
20 ga.
15’
22 ga.
10’
NOTE: Must be stranded wire.
Recommended Maximum Lead Length (Double
Wire) When Using Wall Switch or Thermostat
T149
Fig. 14 Optional wiring to wall switch.
C
B
A
T114
A Thermopile (Do not remove)
B Switch (OFF/ON)
C Wires from receiver (red &
white) or wires from millivolt
wall
Fig. 15 Control valve terminal block.