Temco ADF36-PN Installation Manual Download Page 8

 

Limited Warranty 

TEMCO Vent-Free Gas Fireplaces 

 

This warranty is lim ited to 

TEMCO 

Vent-Free Gas Logs & Fireplaces (henceforth, Product) manufactured by 

TEMCO Fireplace 

Products, Inc. 

(henceforth, TEMCO). 

                                                                      

ONE YEAR WARRANTY 

    

TEMCO 

warrants all components of the Product to be free of defects in materials and workmanship for a period of one year from the 

date of installation, with the exception of the warranty on logs and ember base.   If, by the sole determination of 

TEMCO

,  any 

component covered under this warranty is found to be defective, 

TEMCO

 will, at its option, repair or replace the defective component 

at no charge and will pay labor cost incurred as specified in the current 

TEMCO

  Labor Allowance Schedule, 71313.  If 

TEMCO

 

determines replacement or repair is not economically practical, 

TEMCO

 will, at its option, refund the purchase price of the Product.  

Date of installation and purchase price must be verified by acceptable proof of purchase prior to warranty action. 
                This warranty covers only parts  and labor as provided above.  In no case shall 

TEMCO 

be responsible for materials, 

components or construction which are not manufactured or supplied by 

TEMCO

, or the labor necessary to install, repair or remove 

such materials, components or construction. 

 

FIVE YEAR WARRANTY 

TEMCO 

warrants the ceramic fiber and refractory components and burners originally packed with the product to be free of defects in 

material and workmanship for a period of five (5) years from the 

date of installation

, with the exception of breakage. If any ceramic 

components or refractory components are broken, such breakage must be reported as a Warranty Claim at the time of installation.  
Breakage claims arising after the initial installation will not be covered under any part of th is warranty.  Periodic maintenance must 
have been performed. 

 

 

QUALIFICATIONS  

                For the above warranties to apply: 
                The Product must be installed by a qualified installer; strictly in accordance with TEMCO installation instructions,

 

and in compliance with local codes and ordinances

.  The logs must be placed strictly in accordance with the arrangement 

described in the installation instructions. 
                The Product must be operated and maintained according to the instructions furnished.  

Alteration of the Product in any way 

is prohibited and voids any and all warranties.  Removal of the data plate alters the Product and voids the warranty. 
                The installer must have completed the Installation and Startup Checklist, a copy of which must be submitted along 
with proof of purchase, to obtain prior approval for warranty repair or replacement and to affect a warranty claim.  The 
Checklist is found on pages 11 and 12 of this manual. 
                

The limited warranty applies only to the original owner of the Product or the original owner of the dwelling in which the Product 

was installed.  Use of any parts other than genuine factory provided replacement parts shall void this warranty.  

 

Limitations  

                TEMCO

 is not responsible for any incidental or consequential damages caused by possible defects in the Product.  The 

duration of any implied warranty with respect to the Product is limited to the duration of the foregoing warranties. 
                Some states and provinces do not allow exclusion of incidental or consequential damages or limits on the duration of implied 
warranties, so these limitations may not apply to you. 

 

Warranty Fulfillment 

                Claims require specific agreement and consent from TEMCO Technical Services prior  to performing any warranty 
repair or replacement.  TEMCO reserves the right to investigate any and all warranty claims.  

The appliance must not be 

removed prior to such investigation other than on direction from 

TEMCO

.

 

                Please provide the following information when communicating with 

TEMCO

 Technical Services, its Dealers or Distributors 

regarding service under this warranty.  
 

 
Model Number:_______________________________     Serial Number:_____________________________________ 
 
Date of Installation:______/______/_______ Purchased From:_____________________________________________ 
                 

 

TEMCO

 reserves the right to decide on the method of settlement (if any).  This limited warranty is given in lieu of any other expressed 

or implied warranty, and supersedes all other 

TEMCO

 Product warranties.

 

 

Summary of Contents for ADF36-PN

Page 1: ...by a qualified gas installer service agency or the gas supplier Do not attempt to install this appliance yourself WHAT TO DO IF YOU SMELL GAS Do not light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If the information in this manual is not followed exactly a fi...

Page 2: ...tect your hands and eyes when installing servicing your fireplace No outside air kit is required inside firebox area Refer to the log set manual for combustion air requirements NOTE Authorities having jurisdiction i e building inspectors fire marshals etc should be consulted before installation to determine the need to obtain a permit FAILURE TO FOLLOW THESE INSTRUCTIONS WILL VOID YOUR WARRANTY AN...

Page 3: ...ustion chamber and adequate accessibility clearance for servicing and proper operation Never obstruct the front opening of the fireplace Any safety screen or guard removed for servicing the fireplace must be replaced prior to operating the fireplace This fireplace may be installed in an after market manufactured mobile home where not prohibited by state or local codes After market Completion of sa...

Page 4: ...th the face of the fireplace Only the header see figure 4 may rest on the standoffs on top of the firebox When the fireplace is installed over carpeting vinyl tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extending its full width and depth Alternatively the carpeting vinyl tile etc may be removed beneath the fireplace before installing COMB...

Page 5: ...t directly in front of the opening and then sliding it into the proper position STEP 3 LEVEL THE FIREBOX Check the level of the firebox by placing a level on the top edge of your fireplace face Shim with sheet metal if necessary Do not use wooden shims STEP 4 SECURE THE FIREBOX Secure the fireplace to the framing Nailing flanges on the firebox will make securing it quick and easy Use appropriate s...

Page 6: ...inted metal faces of the fireplace Combustible wall coverings such as paneling or wallboard may not overlap the black face of the fireplace The space between the wall covering and the fireplace should be sealed with a heat resistant material such as rock wool insulation or mortar see figure 6 and 7 MANTEL CLEARANCES With the firebox installed the lower edge of the mantel piece must not be less tha...

Page 7: ... operation Always check for gas leaks after servicing A list of available replacement parts follows Always include the correct name part number and model number of the fireplace when ordering service parts If you desire to communicate with the factory write to TEMCO Fireplace Products P O Box 1349 Manchester TN 37349 or TEMCO Fireplace Products P O Box 1148 Perris CA 92572 REPLACEMENT PARTS See Th...

Page 8: ... codes and ordinances The logs must be placed strictly in accordance with the arrangement described in the installation instructions The Product must be operated and maintained according to the instructions furnished Alteration of the Product in any way is prohibited and voids any and all warranties Removal of the data plate alters the Product and voids the warranty The installer must have complet...

Page 9: ...ODS and front and rear burners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer Note LP models must not be operated if fuel tank is less than 1 4 full Observe the consu...

Page 10: ...f ODS and front and rear burners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer Note LP models must not be operated if fuel tank is less than 1 4 full Observe the con...

Page 11: ... have followed all codes and regulations and adhered to the TEMCO installation instructions I have completed the proper installation and startup checklist Installers Signature Print Installer s Name Purchaser Address Phone Retailer Address Phone Date of Purchase WARRANTY REGISTRATION Please Answer the Following Questions Check Box 1 Type of Home Single Family Duplex Apt Mobile Home Cabin Vacation ...

Reviews: