Temco ADF36-PN Installation Manual Download Page 1

TEMCO 

Vent-Free Gas Fireplaces 

Installation Manual for ADF36-ST and ADF36-PN Fireplaces 

P.O. BOX 1349 Manchester, TN 37349 

P.O. Box 1148 Perris, CA 92572 

A subsidiary of Temtex Industries, Inc.  

REV   9/9/02 10:05 AM       71875K  

See-Through Gas Fireplaces 

ADF36-ST 

Peninsula Gas Fireplaces 

ADF36-PN

 

UNIVERSALLY LISTED FOR US E WITH ANY LISTED 40,000 BTU/HR LP OR NAT GAS LOG APPLIANCE.  

 FOR YOUR SAFETY 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity 
of this or any other appliance. 

Installation and service must be performed by a qualified gas installer, service 
agency or the gas supplier.  Do not attempt to install this appliance yourself! 

WHAT TO DO IF YOU SMELL GAS  

Do not light any appliance. 

Do not touch any electric switch; do not use any phone in your building.  

Immediately call your gas supplier from a neighbor's phone. Follow the gas 
supplier’s instructions. 

 

If the information in this manual is not followed exactly, a fire or explosion may result 

WARNING 

Carefully review the instructions supplied with 

the decorative type unvented room heater for the 

minimum fireplace size requirement. 

 

DO NOT INSTALL THE APPLIANCE IN THIS 

FIREBOX, UNLESS THIS FIREBOX MEETS THE 

MINIMUM DIMENSIONS REQUIRED 

FOR USE ONLY WITH 

DECORATIVE TYPE 

UNVENTED ROOM 

HEATERS 

 

 

Click here to print

Summary of Contents for ADF36-PN

Page 1: ...by a qualified gas installer service agency or the gas supplier Do not attempt to install this appliance yourself WHAT TO DO IF YOU SMELL GAS Do not light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If the information in this manual is not followed exactly a fi...

Page 2: ...tect your hands and eyes when installing servicing your fireplace No outside air kit is required inside firebox area Refer to the log set manual for combustion air requirements NOTE Authorities having jurisdiction i e building inspectors fire marshals etc should be consulted before installation to determine the need to obtain a permit FAILURE TO FOLLOW THESE INSTRUCTIONS WILL VOID YOUR WARRANTY AN...

Page 3: ...ustion chamber and adequate accessibility clearance for servicing and proper operation Never obstruct the front opening of the fireplace Any safety screen or guard removed for servicing the fireplace must be replaced prior to operating the fireplace This fireplace may be installed in an after market manufactured mobile home where not prohibited by state or local codes After market Completion of sa...

Page 4: ...th the face of the fireplace Only the header see figure 4 may rest on the standoffs on top of the firebox When the fireplace is installed over carpeting vinyl tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extending its full width and depth Alternatively the carpeting vinyl tile etc may be removed beneath the fireplace before installing COMB...

Page 5: ...t directly in front of the opening and then sliding it into the proper position STEP 3 LEVEL THE FIREBOX Check the level of the firebox by placing a level on the top edge of your fireplace face Shim with sheet metal if necessary Do not use wooden shims STEP 4 SECURE THE FIREBOX Secure the fireplace to the framing Nailing flanges on the firebox will make securing it quick and easy Use appropriate s...

Page 6: ...inted metal faces of the fireplace Combustible wall coverings such as paneling or wallboard may not overlap the black face of the fireplace The space between the wall covering and the fireplace should be sealed with a heat resistant material such as rock wool insulation or mortar see figure 6 and 7 MANTEL CLEARANCES With the firebox installed the lower edge of the mantel piece must not be less tha...

Page 7: ... operation Always check for gas leaks after servicing A list of available replacement parts follows Always include the correct name part number and model number of the fireplace when ordering service parts If you desire to communicate with the factory write to TEMCO Fireplace Products P O Box 1349 Manchester TN 37349 or TEMCO Fireplace Products P O Box 1148 Perris CA 92572 REPLACEMENT PARTS See Th...

Page 8: ... codes and ordinances The logs must be placed strictly in accordance with the arrangement described in the installation instructions The Product must be operated and maintained according to the instructions furnished Alteration of the Product in any way is prohibited and voids any and all warranties Removal of the data plate alters the Product and voids the warranty The installer must have complet...

Page 9: ...ODS and front and rear burners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer Note LP models must not be operated if fuel tank is less than 1 4 full Observe the consu...

Page 10: ...f ODS and front and rear burners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer Note LP models must not be operated if fuel tank is less than 1 4 full Observe the con...

Page 11: ... have followed all codes and regulations and adhered to the TEMCO installation instructions I have completed the proper installation and startup checklist Installers Signature Print Installer s Name Purchaser Address Phone Retailer Address Phone Date of Purchase WARRANTY REGISTRATION Please Answer the Following Questions Check Box 1 Type of Home Single Family Duplex Apt Mobile Home Cabin Vacation ...