TEMA TELECOMUNICAZIONI SRL
Doorphone AA-540
MAS-AA540-REV09
Page 42 of 60
9.4. SIP parameters
Once the network parameters have been set correctly, you must configure the connection with the SIP-VoIP PBX:
•
SIP server address: specify the IP address of the SIP PBX to which AA-540 should connect.
•
Port: is the port number of the SIP PBX AA-540 which has to forward incoming calls. Generally it is the
5060, but some stations use a different port.
•
Domain: domain where register the client
•
Outbound proxy: some PBXs require that the extension number to call is followed by the proxy address. In
most cases this field can be left empty.
•
Local SIP port: generally the 5060 port is used, but it is possible to specify a different number (i.e. for
particular routing tables)
•
User/password: credentials for the registration of the extension (which obviously must have been already
created on the PBX)
•
Expiration: indicates how many seconds the device should check the correct registration of the client
•
2
ND
SIP account: this account is used for “Night ringer”. It is possible to configure, in the PBX, a ringer
group used in night mode, so if the doorphone is put in the same group, it will play the ringer message
(see par. Errore. L'origine riferimento non è stata trovata.) when receiving an incoming call, without
answering.
•
Password: the second account password.
•
Volume: volume of the ringer.
•
Ampli on: no function in this model