TEMA TELECOMUNICAZIONI SRL
Doorphone PBX interface AA-11
MAS-AA11-REV02EN
Page 10 of 12
8.2.
Table of programming parameters
The parameters are stored in a non-volatile memory and are not lost even in case of loss of power.
To enter programming mode:
- call the extension on which AA-11 is installed
- dial “1 # #”
Digit Parameter
name
Description
Range = allowed values
Default
Your setting
1 nnn #
nnn = first extension
to call
The extension to be called by the device when an external
visitor pushes the button at the doorphone. NOTE: dialling
“
*
” digit the system will pause for 1 sec. before next digit.
Range: max 20 digits
9
(operator)
2 nnn #
nnn = second
extension to call
Second extension to be called if the first called number
does not answer. Put # without other digits for no call.
NOTE: dialling “
*
” digit the system will pause for 1 sec.
before next digit.
Range: max 20 digits
#
(disabled)
3 nnn #
nnn = third
extension to call
Third extension to be called if the second called number
does not answer. Put # without other digits for no call.
NOTE: dialling “
*
” digit the system will pause for 1 sec.
before next digit.
Range: max 20 digits
#
(disabled)
4 n
Door lock mode
n = 1, pulse once
n = 2, pulses twice
n = 3, pulses 3 times
The door lock relay is activated with one or with more
consecutive pulses. Set “n” for your needings.
Range: max 1 digit
2
(2 pulses)
5 n
AUX1 relay mode
n = 1, pulse once
n = 2, steady
Relay AUX1 is activated with a pulse or steadily closed
(until it is commanded to de-activate). Set “n” for your
needings.
Range: max 1 digit
1
(1 pulse)
6 n
AUX2 relay mode
n = 1, pulse once
n = 2, steady
Relay AUX2 is activated with a pulse or steadily closed
(until it is commanded to de-activate). Set “n” for your
needings.
Range: max 1 digit
1
(1 pulse)
7 n
Relay pulse duration
n = 1, for 0.25 sec.
n = 2, for 0.50 sec.
n = 3, for 1.00 sec.
Duration of the pulse (for all relays).
Note: the door-lock relay is always subjected to this
setting, the AUX relays only if programmed in pulse mode
Range: max 1 digit
1
(0.25 sec)
0 n
Call/Convers. Time
n = 1, 16 / 16 sec
n = 2, 32 / 16 sec
n = 3, 64 / 16 sec
n = 4, 16 / 32 sec
n = 5, 32 / 32 sec
n = 6, 64 / 32 sec
n = 7, 16 / 64 sec
n = 8, 32 / 64 sec
n = 9, 64 / 64 sec
n = 0, 64 / 192 sec
Combination of the maximum time allowed before the
answer of the programmed extensions and the maximum
time of conversation with the external doorphone.
Choose among the built-in combinations.
Range: max 1 digit
6
(64/32 sec)
*
n
End selection digit
n=0, none
n=1, # digit
n=2,
*
digit
Inserts digit “
*
” or “#” at the end of the selection.
Range: max 1 digit
0
(none)
8
Reset all values to
the factory default
WARNING:
issue this command only if you want to reset
all values to the factory default, losing your settings.
This command acts without asking any confirmation:
use it with care!
- -
9
End programming
Disconnects the call and saves any changes to the
parameters. The settings are saved even without the
“9” command, but the device would hang up and be
available for new calls only after a timeout.
- -
For example, if you want that the door-lock is activated twice: call the extension on which AA-11 is
installed, dial 1## to enter programming mode, dial 42 to set the door lock mode parameter, then
dial 9 to end the call and finally hang up. After that, whenever the command 2 is dialed the door-
lock relay will be closed twice in succession.