A1.0 Appendices
A1.1 W
IRING
D
IAGRAM
24 HOUR ZONE (N.C.)
TELCO DIALER
ANTENNA
T
R
1 2 3 4 5 6 7
TELGUARD
Digital TG-1
OPEN = NORMAL
SIGNAL
STRENGTH
LEDS
www.Telguard.com
REFER TO INSTALLATION AND OPERATING
INSTRUCTIONS MANUAL. THIS DEVICE COMPLIES
WITH FCC RULE PART 15.
TELULAR CORPORATION
420 Thornton Road, Suite 109
Lithia Springs, GA 30122
(800) 229-2326 Fax: 678-945-1651
8 9
+
_
JP4
J7
SIM
J10
SHORTED = RSSI
HOST C/C
1
2
3
4
5
SYSTEM STATUS LEDS
NORMAL MODE
LED #5 GREEN
ON = RADIO INITIALIZING
FLASH = COMMUNICATING
LED #4 RED
ON = WAITING FOR RESPONSE
If flashing with LED 1 = DENIED
(NACK)
LED #3 YELLOW
OFF = MODE 2 (CELL Primary)
FLASH = C/C OFF HOOK CELL
LED #2 RED
SYSTEM TROUBLE, STC
(See Table)
LED #1 GREEN
REGISTRATION (See Table)
SYSTEM TROUBLE,
STC (LED #2)
1 FLASH = AC LOW/MISSING
2 FLASH = LBC LOW BATTERY
3 FLASH = Not Used
4 FLASH = NSC NO SERVICE
5 FLASH = RFC RADIO FAILURE
6 FLASH = DTF DIAL TONE FAIL
REGISTRATION
(LED #1)
ON = UNIT REGISTERED
OFF = UNIT NOT REGISTERED
If flashing with LED 4 = DENIED
(NACK)
,
Call Technical Support.
If all LED's flashing = NO RESPONSE,
Check Signal Strength.
SYSTEM STATUS LEDS
RSSI MODE
RSSI Value LED's Lighted
RF dBm
NO SVC LED 5*= flash, 4-2 = off n/a
1
LED 5 = on, 4-2 = off
< -111 dBm
1 ½
LED 5 = on, 4 = flash, 3-2 = off > -110 dBm
2
LED 5-4 = on, 3-2 = off > -100 dBm
2 ½
LED 5-4 = on, 3 = flash, 2 = off
> -90 dBm
(Minimum Signal Recommended)
3
LED 5-3 = on, 2 = off
> -80 dBm
3 ½
LED 5-3 = on , 2 = flash > -70 dBm
4
LED 5-2 = on
> -60 dBm
*Note: LED 1 ON INDICATES MORE THAN ONE TOWER
AC
LED 6
CAUTION:
INCORRECT CONNECTIONS
MAY RESULT IN DAMAGE TO UNIT.
LED MODE SELECT
EARTH
GROUND
STC2
(N.C.)
BATTERY
(12V)
BLANK PIN
AC
(12V 800MA)